Scope of delivery 

 

 A 

Aquarius Fountain Set Eco 5500/7500/9500 

Fountain pump 

Telescopic extension 

Nozzles 

Transition piece with fine filter screen 

Flow regulator, ball joint with union nut, transition piece, sleeve, double nipple 

Stepped hose adapter 

 

 

 

 

Product Description 

 

Aquarius Fountain Set Eco 5500/7500/9500 is a fountain pump for garden ponds, ornamental fountains and water 

courses. 

  Temperature protection by integrated temperature monitor. 

   Pivoting telescopic extension with various nozzles. 

  Second, separately adjustable outlet. 

 

 

 

Intended use 

 

Aquarius Fountain Set Eco 5500/7500/9500, referred to as "unit", may only be used as specified in the following: 

 

  For pumping normal pond water for water features and fountains. 

 

  Operate in accordance with instructions.  

 

  Operation under observance of the permissible water quality. (

 

Water quality)

 

 

 

 

The following restrictions apply to the unit: 

 

  Do not use in swimming ponds. 

 

  Never use the unit to convey fluids other than water. 

 

  Never run the unit without water. 

 

  Do not use for commercial or industrial purposes. 

 

  Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances. 

 

  Do not connect to the domestic water supply. 

 

 

 

Installation and connection 

 

Reassembling the unit 

How to proceed: 

 

 C 

 

1. Fit the sleeve, flow regulator, double nipple, union nut, ball joint and transition piece together and screw onto the 

pump outlet. 

2. Screw the telescopic extension with the desired nozzle onto the flow regulator. 

3. Screw the stepped hose adapter onto the flow regulator for feeding a water course if applicable. 

4. Align the telescopic extension and hand tighten the union nut on the ball joint. 

 

 

 

Summary of Contents for Aquarius Fountain Set Eco 5500

Page 1: ...41764 06 15 Aquarius Fountain Set Eco 5500 7500 9500 41764 GAW Aquarius_FountainSet_Eco_A5_end_ 18 06 15 18 12 Seite 2 ...

Page 2: ... 2 A ARS0014 B ARS0015 ...

Page 3: ... 3 C ARS0016 D ARS0017 ...

Page 4: ... 4 E ARS0022 F ARS0018 ...

Page 5: ... 5 G ARS0019 ...

Page 6: ...rvision Ensure that the unit is fused for a rated fault current of max 30 mA by means of a fault current protection device Only connect the unit if the electrical data of the unit and the power supply correspond The unit data is to be found on the unit type plate on the packaging or in this manual Possible death or severe injury from electrocution Before reaching into the water always disconnect a...

Page 7: ... accessories for the unit The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace makers or implantable cardioverter defibrillators ICDs Always keep magnets at least 0 2 m away from implanted devices Information about this operating manual Welcome to OASE Living Water You made a good choice with the purchase of this product Aquarius Founta...

Page 8: ...untains Operate in accordance with instructions Operation under observance of the permissible water quality Water quality The following restrictions apply to the unit Do not use in swimming ponds Never use the unit to convey fluids other than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in conjunction with chemicals foodstuff easily flammable o...

Page 9: ...again once it has cooled down Isolate the unit before starting any work N O T E Sensitive electrical components Incorrect connection will destroy the unit Do not connect the unit to a dimmable power supply This is how to connect the power supply Switching on Connect the unit to the mains The unit switches on immediately Switching off Disconnect the unit from the mains Environmental Function Contro...

Page 10: ...too high Note maximum water temperature of 35 C The pump automatically switches on again once the motor has cooled down The impeller unit is blocked Disconnect the power supply and remove ob stacle Then switch the pump on again Pump has run dry Disconnect the power plug and flood the pump Fully submerge the pump for operation in the pond Then switch the pump on again Maintenance and cleaning W A R...

Page 11: ...rage overwintering The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store the unit Thoroughly clean the unit check it for damage and replace any damaged parts Store the pump submerged and in a frost free environment Protect open plug connections from moisture and dirt Wear parts Impeller unit Spare parts The use of original ...

Page 12: ...nät Kaapelin pituus Mitat Paino HU Típus Csatlakoztatási feszültség Teljesítményfelvétel Szállítási teljesítmény Vízoszlop Csatlakozók Kábelhossz Méretek Súly PL Typ Napięcie przyłączeniowe Pobór mocy Wydajność pompowania Słup wody Przyłącza Długość kabla Wymiary Ciężar CS Typ Připojovací napětí Příkon Dopravní výkon Vodní sloupec Přípojky Délka kabelu Rozměry Hmotnost SK Typ Napájacie napätie Prí...

Page 13: ...kasia Mahdollinen vaara sydämentahdistinta käyttäville henkilöille Älä hävitä laitetta tavallisen talousjät teen kanssa Huomio Lue käyttöohje HU Portömített Vízálló 2 m es mélységig Fagy esetén a készüléket szerelje le A készülék veszélyes lehet szívritmus szabályozóval rendelkező személyekre A készüléket nem a normál háztartási szeméttel együtt kell megsemmisíteni Figyelem Olvassa el a használati...

Page 14: ...rdhet Temperatur FI Suositellut vesiarvot pH arvo Kokonaiskovuus Lämpötila HU A vízre vonatkozó ajánlott értékek pH érték Teljes keménység Hőmérséklet PL Zalecane parametry wody Wartość pH Twardość ogólna Temperatura CS Doporučené hodnoty vody Hodnota pH Celková tvrdost Teplota SK Odporúčané hodnoty vody Hodnota pH Celková tvrdosť Teplota SL Priporočene vrednosti za vodo pH vrednost Skupna trdota ...

Reviews: