background image

-  EN  - 

15 

 

 

Set-up the unit 

 

 B 

 

 

 

 

W A R N I N G

 

Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond. 

  Never operate this unit in a swimming pond. 

 

 

 

 

N O T E

 

If the pump is used for conveying excessively soiled water, the impeller unit will be subject to increased wear 

and will require earlier replacement. 

Remedy: 

  Thoroughly clean the pond or pool before installing the pump. 

  Install the pump approx

. 200 mm above the floor of the pond to avoid excessively soiled water from being 

drawn into the pump. 

 

 

 

  Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely covered 

with water. 

 

 

 

Commissioning/start-up 

 

 

 

 

C A U T I O N

 

Risk of injury due to fast rotating components. 

A temperature monitor switches the unit off automatically in the event of overload and on again once it has 

cooled down. 

  Isolate the unit before starting any work. 

 

 

 

 

N O T E  

Sensitive electrical components. Incorrect connection will destroy the unit. 

  Do not connect the unit to a dimmable power supply. 

 

 

 

This is how to connect the power supply: 

 

Switching on:

 Connect the unit to the mains. The unit switches on immediately. 

Switching off:

 Disconnect the unit from the mains. 

 

 

 

Environmental Function Control (EFC) 

 

When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length 

(Envi-

ronmental Function Control (EFC))

. The pump detects if it is running dry / blocked or submerged. The pump 

switches off automatically after approx. 90 seconds if it runs dry (is blocked). 

In the event of a malfunction, disconnect 

the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted. 

 

 

 

Adjustments 

 

 D, E 

 

Setting the spray pattern and flow rate: 

  Adjust the flow regulator so that the nozzle produces the desired spray pattern. 

  Adjust the flow regulator to achieve the desired flow rate for the water course. 

 

 

 

Summary of Contents for Aquarius Fountain Set Eco 5500

Page 1: ...41764 06 15 Aquarius Fountain Set Eco 5500 7500 9500 41764 GAW Aquarius_FountainSet_Eco_A5_end_ 18 06 15 18 12 Seite 2 ...

Page 2: ... 2 A ARS0014 B ARS0015 ...

Page 3: ... 3 C ARS0016 D ARS0017 ...

Page 4: ... 4 E ARS0022 F ARS0018 ...

Page 5: ... 5 G ARS0019 ...

Page 6: ...rvision Ensure that the unit is fused for a rated fault current of max 30 mA by means of a fault current protection device Only connect the unit if the electrical data of the unit and the power supply correspond The unit data is to be found on the unit type plate on the packaging or in this manual Possible death or severe injury from electrocution Before reaching into the water always disconnect a...

Page 7: ... accessories for the unit The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace makers or implantable cardioverter defibrillators ICDs Always keep magnets at least 0 2 m away from implanted devices Information about this operating manual Welcome to OASE Living Water You made a good choice with the purchase of this product Aquarius Founta...

Page 8: ...untains Operate in accordance with instructions Operation under observance of the permissible water quality Water quality The following restrictions apply to the unit Do not use in swimming ponds Never use the unit to convey fluids other than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in conjunction with chemicals foodstuff easily flammable o...

Page 9: ...again once it has cooled down Isolate the unit before starting any work N O T E Sensitive electrical components Incorrect connection will destroy the unit Do not connect the unit to a dimmable power supply This is how to connect the power supply Switching on Connect the unit to the mains The unit switches on immediately Switching off Disconnect the unit from the mains Environmental Function Contro...

Page 10: ...too high Note maximum water temperature of 35 C The pump automatically switches on again once the motor has cooled down The impeller unit is blocked Disconnect the power supply and remove ob stacle Then switch the pump on again Pump has run dry Disconnect the power plug and flood the pump Fully submerge the pump for operation in the pond Then switch the pump on again Maintenance and cleaning W A R...

Page 11: ...rage overwintering The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store the unit Thoroughly clean the unit check it for damage and replace any damaged parts Store the pump submerged and in a frost free environment Protect open plug connections from moisture and dirt Wear parts Impeller unit Spare parts The use of original ...

Page 12: ...nät Kaapelin pituus Mitat Paino HU Típus Csatlakoztatási feszültség Teljesítményfelvétel Szállítási teljesítmény Vízoszlop Csatlakozók Kábelhossz Méretek Súly PL Typ Napięcie przyłączeniowe Pobór mocy Wydajność pompowania Słup wody Przyłącza Długość kabla Wymiary Ciężar CS Typ Připojovací napětí Příkon Dopravní výkon Vodní sloupec Přípojky Délka kabelu Rozměry Hmotnost SK Typ Napájacie napätie Prí...

Page 13: ...kasia Mahdollinen vaara sydämentahdistinta käyttäville henkilöille Älä hävitä laitetta tavallisen talousjät teen kanssa Huomio Lue käyttöohje HU Portömített Vízálló 2 m es mélységig Fagy esetén a készüléket szerelje le A készülék veszélyes lehet szívritmus szabályozóval rendelkező személyekre A készüléket nem a normál háztartási szeméttel együtt kell megsemmisíteni Figyelem Olvassa el a használati...

Page 14: ...rdhet Temperatur FI Suositellut vesiarvot pH arvo Kokonaiskovuus Lämpötila HU A vízre vonatkozó ajánlott értékek pH érték Teljes keménység Hőmérséklet PL Zalecane parametry wody Wartość pH Twardość ogólna Temperatura CS Doporučené hodnoty vody Hodnota pH Celková tvrdost Teplota SK Odporúčané hodnoty vody Hodnota pH Celková tvrdosť Teplota SL Priporočene vrednosti za vodo pH vrednost Skupna trdota ...

Reviews: