Attention! The pump must never run dry.
Possible consequence:
The pump will be destroyed.
Protective measure:
Check the water level at regular intervals. Always place the unit below water level.
Set the flow at the controller (D).
This is how to connect the power supply:
Switching on:
Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off:
Disconnect the power plug.
Attention!
The installed temperature monitor automatically turns the pump off, if it is overloaded. The pump
automatically switches on again once the motor has cooled down.
Risk of accident!
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
−
Prior to reaching into the water, disconnect the power supply to all units used in the water.
−
Disconnect the power plug prior to carrying out work on the unit.
Cleaning the unit
Dismantle and clean the unit (E).
If necessary, clean the unit with clear water using a soft brush.
−
In the event of stubborn furring (calcium deposits), a common household cleaner free from vinegar and chlorine can
be used. Subsequently, clean the pump thoroughly using clear water.
−
Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
Malfunction
Malfunction Cause
Remedy
No mains voltage
Check mains voltage
The unit does not start
Rotor blocked
Clean
Regulator closed too far
Set regulator
Filter housing or rotor soiled, hose blocked
Clean
Hose defective
Replace
Hose kinked
Straighten hose
Insufficient fountain height
Rotor worn
Replace rotor
Filter clogged
Clean
Unit switches off after a short running period
Water temperature too high
Maximum water temperature: +35 °C
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!
Repair
A damaged housing cannot be repaired and must be put out of operation. Dispose of the unit in accordance with the
regulations.
Summary of Contents for Aquarius Universal 600
Page 3: ...3...
Page 59: ...59 BG 30 mA H05RN F DIN VDE 0620 OASE A 5 1 2 A 1 2 2...
Page 60: ...60 BG D max 40 C E 35 C...
Page 62: ...62 UA 30 H05 RN F DIN VDE 0620 OASE 5 1 2 1 2 2...
Page 63: ...63 UA D max 40 C E 35 C...
Page 65: ...65 RU 30 H05RN F DIN VDE 0620 OASE A B A 5 B1 B2 A C A C1 C2 C2...
Page 66: ...66 RU D Aquamax max 40 C E 35 C...
Page 68: ...68 CN 30 H05RN F DIN VDE 0620 A B A 5 mm B1 B2 A C A C1 C2 C2...
Page 69: ...69 CN D max 40 C E 35 C...
Page 72: ...72...
Page 73: ...15307 04F...