Technical data 

Aquarius Universal Classic

 

3000 

Connection voltage 

V AC 

220 … 240 

Mains frequency 

Hz 

50 

Max. power consumption 

40 

Max. pump capacity 

l/h 

3000 

Max. pump head 

3.2 

Protection type 

IP68 

Max. immersion depth 

Inlet port 

Thread 

G1½ 

Connection, hose 

mm 

25, 32, 38 

Outlet port 

Thread 

G1 

Connection, hose 

mm 

19, 25, 32, 38 

Filter supply surface area 

cm

²

 

200 

Water temperature 
(submerged installa-
tion) 

During operation 

°C 

+4 ... +35 

Out of operation 

°C 

-20 ... +35 

Ambient temperature 
(dry installation) 

During operation and 
convection 

°C 

-20 ... +30 

During operation and 
forced cooling 

°C 

-20 ... +40 

Dimensions 

Length 

mm 

245 

Width 

mm 

130 

Height 

mm 

135 

Connection cable length 

10 

Weight 

kg 

3.0 

Permissible water quality 

Type 

Fresh water 

pH value 

6.8 … 8.5 

Hardness 

DH 

8 … 15 

Free chlorine 

mg/l 

<0.3 

Chloride content 

mg/l 

<250 

Salt content 

<0.4 

Overall dry residue 

mg/l 

<50 

Temperature 

°C 

+4 … +35 

Downloaded from www.watergardeningdirect.com

Summary of Contents for Aquarius Universal Classic 3000

Page 1: ...Aquarius Universal Classic 3000 Operating instructions Downloaded from www watergardeningdirect com...

Page 2: ...ed by children aged 8 and above and by persons with reduced physical sensory or mental capabilities or lack of expe rience and knowledge if they are supervised or have been instructed on how to use th...

Page 3: ...s and power distributors e g outlet strips must be suitable for outdoor use splash proof Protect open plugs and sockets from moisture Safe operation Do not use the unit if electrical lines or the hous...

Page 4: ...se in swimming ponds Never use the unit with fluids other than water Never run the unit without water Do not use in conjunction with chemicals foodstuff easily flammable or explosive substances Do not...

Page 5: ...merged installation With hose sleeve for connecting a hose for dry installation 2 Outlet pressure side Connection of the return line e g to a fountain 3 Filter cage 4 Flow rate controller 5 Power cabl...

Page 6: ...waste Read the operating instructions Installation variants ARS0084 Variant a Submerged pump installation The pump is positioned in the pond or basin Water flow via the filter cage Variant b Dry pump...

Page 7: ...stopped due to overload can start up unex pectedly Do not reach into the opening of the intake socket or pressure socket while the power plug is plugged in If the sockets are freely accessible during...

Page 8: ...tation Use Top or side right left Recommended for dry installation When used with submerged installation ensure that the water level is sufficient Bottom Recommended for submerged installation Pumps w...

Page 9: ...t plug the power plug into the socket yet Installation ARS0086 Place the pump horizontally on a stable mud free surface Ensure secure and stable positioning of the pump Only operate the pump when it i...

Page 10: ...EN 25 Install the unit at a dry place Connecting ARS0087 Do not plug the power plug into the socket yet Downloaded from www watergardeningdirect com...

Page 11: ...lace the pump horizontally on a stable mud free surface Ensure secure and stable positioning of the pump It is possible to screw the unit to a suitable surface to ensure stability Downloaded from www...

Page 12: ...the unit and automatically reactivate it Disconnect the power plug before carrying out any work on the unit NOTE Do not use aggressive cleaning agents or chemical solutions These agents can damage th...

Page 13: ...ntle the pump as shown in the figure Use a brush under clear water to clean the components Check all components for damage Replace damaged or worn components Assemble the pump in reverse order ARS0089...

Page 14: ...nt flow rate Flow rate is set too low on the controller Increase flow rate on the controller Filter housing clogged Clean strainer casings Excessive loss in the supply lines Reduce hose length to the...

Page 15: ...a cm 200 Water temperature submerged installa tion During operation C 4 35 Out of operation C 20 35 Ambient temperature dry installation During operation and convection C 20 30 During operation and fo...

Page 16: ...e of the unit by using the return system provided for this purpose Should you have questions please contact your local disposal company They will give you in formation on how to correctly dispose of t...

Page 17: ...331 XX ARS0091 Downloaded from www watergardeningdirect com...

Page 18: ...OASE GmbH Tecklenburger Stra e 161 48477 H rstel Germany 49 0 5454 80 0 49 0 5454 80 9353 info oase com 90555 05 22 Downloaded from www watergardeningdirect com...

Reviews: