Cleaning the quartz glass 

 

 

 

Attention!

 Breakable glass. 

Possible consequences:

 Injury to your hands caused by cuts. 

Protective measures:

 Handle the quartz glass and UVC lamp with care. 

 
 

 

 

Note! 

If the water flow is suddenly interrupted downstream of the outlet (e.g. with a slide valve), this can lead to a 
brief increase of pressure of more than 1 bar (water hammer). 

Possible consequences:

 The unit may be damaged. 

Protective measures: 

  Switching off: First switch off the pump, then close the slide valve. If the unit is operated in a filter system, 

first take the filter system out of operation. 

  Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a filter system, 

start up the filter system last. 

  Install the slide valve upstream of the inlet. 

 
 

Prerequisite: The device head is removed. (

 Removing the unit head) 

8.  
0. 

How to proceed: 

 O 

1.  Turn the casing cover counterclockwise as far as the stop. 

  Rotational direction symbol "Open lock". 

  The casing cover can be very firmly seated. If necessary, insert a rod through the lugs to achieve greater levera-

ge. 

2.  Carefully pull the quartz glass and cleaning rotor out of the casing. 
3.  Clean the quartz glass and the cleaning rotor. 

  Pull off the cleaning rotor and clean with a brush under running water. 

  Wipe the quartz glass with a damp cloth. 

  Thoroughly clean the inner and outer surfaces of the casing. 

4.  Replace the quartz glass if it is damaged or very scratched. 

  Undo the clamping screw and pull the quartz glass, together with the O ring, from the casing cover. 

  Clean the O ring and lubricate with OASE grease (order No. 27872). Replace the O ring if it is damaged. 

5.  Fit the quartz glass together with the O ring onto the casing cover and screw in the clamping screw as far as the 

stop. 

  Pull the O ring over the flanged rim to avoid grease residue coming into contact with the quartz glass. 

  Ensure that the clamping screw audibly engages, otherwise the casing cover cannot be fitted into the casing. 

6.  Check the profile wear at both ends and the inner surfaces on the cleaning rotor. 

  If the profile is worn, the cleaning rotor rotates sluggishly and has to be replaced. 

7.  Push the cleaning rotor onto the quartz glass. 

  Ensure that it is correctly positioned. 

8.  Carefully push the quartz glass and the cleaning rotor into the casing.  
9.  Turn the casing cover clockwise as far as the stop. 

  Rotational direction symbol "Close lock". 

 

Wear parts 

The following components are wear parts and are excluded from the warranty: 

  UVC lamp, quartz glass and O ring for quartz glass 

 Cleaning 

rotor 

 Lamp 

holder 

 

Storage/Over-wintering 

The unit is protected from frost: 

The unit can be operated as long as the water temperature does not go below +4 °C. 

The unit is not protected from frost: 

Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage. 

 

Disposal 

 

 

 

Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided. 
Disable the unit beforehand by cutting off the cables. 

 

 

Dispose of the UVC lamp by using the return system provided for this purpose. 

 

30481-11-13_GA_Bitron Eco 120, 134   34

18.11.2013   11:29:46

Downloaded from www.watergardeningdirect.com

Summary of Contents for Bitron Eco 180W

Page 1: ...Bitron Eco 120W 180W 240W 00000 GAW_Bitron_Eco_A5_end_ 21 10 13 13 53 Seite 1 Downloaded from www watergardeningdirect com...

Page 2: ...2 A BTN0003 B BTN0001 C BTN0008 D E BTN0004 BTN0013 30481 11 13_GA_Bitron Eco 120 12 2 18 11 2013 11 29 43 Downloaded from www watergardeningdirect com...

Page 3: ...3 F BTN0015 G BTN0017 30481 11 13_GA_Bitron Eco 120 13 3 18 11 2013 11 29 43 Downloaded from www watergardeningdirect com...

Page 4: ...4 H BTN0005 I BTN0016 30481 11 13_GA_Bitron Eco 120 14 4 18 11 2013 11 29 44 Downloaded from www watergardeningdirect com...

Page 5: ...5 J K BTN0006 BTN0010 L BTN0009 30481 11 13_GA_Bitron Eco 120 15 5 18 11 2013 11 29 44 Downloaded from www watergardeningdirect com...

Page 6: ...6 M BTN0012 N BTN0002 30481 11 13_GA_Bitron Eco 120 16 6 18 11 2013 11 29 44 Downloaded from www watergardeningdirect com...

Page 7: ...7 O BTN0011 30481 11 13_GA_Bitron Eco 120 17 7 18 11 2013 11 29 45 Downloaded from www watergardeningdirect com...

Page 8: ...s Risk of injury to persons due to dangerous electrical voltage This symbol indicates an imminent danger which can lead to death or severe injuries if the appropriate meas ures are not taken Risk of p...

Page 9: ...50 mm 2 for fastening the hose connector 7 8 10 2 Flat seal 57 48 3 mm for the union nut 9 11 1 Inlet nozzle for driving the cleaning rotor Has to be inserted into the inlet for flow rates 10000 l h 1...

Page 10: ...of 12000 hours The electronic ballast is virtually lossless It is not necessary to remove the quartz glass for changing the UVC lamps The filter system can remain in operati on continuously Intended...

Page 11: ...consult a qualified electrician The unit may only be connected when the electrical data of the unit and the power supply coincide The unit data is to be found on the unit type plate or on the packagi...

Page 12: ...the unit into consideration Technical data Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be installed below the water level This allows the water supply to...

Page 13: ...Classic Screw the cover cap onto the outlet instead of the inlet nozzle 4 Connect the Bitron to the filter pump Connecting the inlet BioTec ScreenMatic Please adhere to the instructions for use of th...

Page 14: ...e LEDs lit 6001 9000 hours Two LEDs lit 3001 6000 hours One LED lit 1 3000 hours One LED flashing Replace UVC lamps All LEDs unlit At least one UVC lamp is defective 4 Display Display of the operating...

Page 15: ...edium saving in energy 25 Operating mode 90 Low saving in energy 10 Water temperatu re C ON h OFF h Irradiation duration ON h OFF h Irradiation duration ON h OFF h Irradiation duration 4 12 72 14 12 1...

Page 16: ...on Storage overwintering L Lo o Ambient temperature 9 C Temperature display out of operation operation is not practical Start up Note If the water flow is suddenly interrupted downstream of the outlet...

Page 17: ...Cleaning the quartz glass Power plug not connected Connect the power plug Unit is not functional Connection defective Check the electrical connection Lamp does not light up Safety switch off activate...

Page 18: ...ystem overview Function of the cleaning rotor A visual inspection is possible when the unit head is removed Removing the unit head Use a torch to improve visibility Dismantling the unit head Attention...

Page 19: ...nal direction symbol Close lock The locking device fixes the retaining plate such that the UVC lamps are firmly seated in the lamp sockets Replacing a defective UVC lamp Only use UVC lamps whose ident...

Page 20: ...the O ring from the casing cover Clean the O ring and lubricate with OASE grease order No 27872 Replace the O ring if it is damaged 5 Fit the quartz glass together with the O ring onto the casing cove...

Page 21: ...tity 2 2 2 mm 38 50 38 50 38 50 Outlet Connection in 1 2 1 2 1 2 Flow rate max l h 50000 50000 50000 Operating pressure max bar 1 1 1 Dimensions L W H mm 725 227 248 725 227 248 725 227 248 without wa...

Page 22: ...196 BTN0014 30481 11 13_GA_Bitron Eco 120 1196 196 18 11 2013 11 29 52 Downloaded from www watergardeningdirect com...

Page 23: ...30481 11 13 30481 11 13_GA_Bitron Eco 120 1200 200 18 11 2013 11 29 53 Downloaded from www watergardeningdirect com...

Reviews: