- EN -
17
COMMISSIONING/START-UP
C
•
Route the power connection cable such that
it forms a drip loop!
•
Switching on:
Connect the unit to the mains.
The unit switches on immediately.
•
Switching off:
Disconnect the unit from the
mains.
MAINTENANCE AND CLEANING
If necessary, clean the unit with clear water using
a soft brush.
•
Do not use cleaning agents or chemical solu-
tions. We recommend using OASE PumpClean
for removing calcium deposits.
Replacing the impeller unit
E
How to proceed:
1.
Loosen and remove the screws at the side of
the pump lid.
2.
Remove the pump lid.
3.
Remove the impeller unit.
–
If necessary, use a wide-blade screwdriver
to lever the impeller unit out of its position
in the motor housing. For this, insert the
screwdriver blade into the groove be-
tween the impeller unit and motor hous-
ing, and firmly turn the screwdriver in or-
der to dislodge the impeller from its posi-
tion.
–
Proceed carefully so as not to damage the
motor housing or O ring.
4.
Clean or replace the impeller unit and subse-
quently reassemble the pump in the reverse
order.
–
OptiMax 4000/5000: Firmly push the im-
peller unit into position in the motor hous-
ing.
Summary of Contents for OptiMax 2000