- EN -
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email
us at customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
31
Malfunction Possible
cause
Remedy
Hel-X biomedia are being
flushed out.
The meshed tube has slipped.
Correct the position of the meshed tube.
Defective meshed tube
Replace the meshed tube.
Less movement of the Hel-
X biomedia
Aerator rod is blocked.
Replace the aerator rod.
Aerator pump malfunction
Check the aerator pump.
Less movement of the new
Hel-X biomedia
Hel-X biomedia are not yet fully colonised.
It takes several weeks for the biomedia to become
colonised by bacteria. Wait for the natural process
to take place.
8
Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
►
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the
water.
►
Isolate the device (disconnect from the power supply) before carrying out any work on it.
8.1
Cleaning the device
►
Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or
impair the function of the unit.
►
Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
►
After cleaning, thoroughly rinse all parts in clean water.
8.2 Regular
tasks
The filter system is self-cleaning. Carry out the following work regularly to ensure the optimum cleaning
capacity of the filter system.
Regular checks
►
Check the display of the control system for any system messages. (
→
System messages)
►
Check the area in front of the separating plate and the inside of the filter drum for excessive soiling
(e.g. string algae). To do this, remove a screen element. (
→
Removing/fitting a screen element)
Removing accumulated dirt
Dirt that cannot be collected by the filter drum, sinks to the bottom and has to be removed.
►
Open the 3 in (DN 75) dirt outlet for approx. 10 seconds once per month.
►
Remove accumulated dirt in front of the filter drum.
►
Remove string algae from the dirt channel.
►
Remove accumulated dirt from the level detection device.
Summary of Contents for ProfiClear Premium Compact-M EGC
Page 2: ...2 A ProfiClear0176...
Page 3: ...3 B ProfiClear0177 C ProfiClear0172...
Page 4: ...4 D ProfiClear0112 E BTC0027...
Page 5: ...5 F G ProfiClear0167 ProfiClear0168 H ProfiClear0169 I ProfiClear0170...
Page 7: ...7 N BTC0031 O PrifiClear0083 P BTC0025...
Page 8: ...8 Q ProfiClear0084 R ProfiClear0085 S T BTC0023 BTC0024...
Page 9: ...9 U ProfiClear0178 s...
Page 92: ...OASE GmbH www oase livingwater com Tecklenburger Stra e 161 48477 H rstel Germany 72631 02 19...