23
- GB -
5
Installation and connection
5.1 Installation
planning
Note:
Use suitable transport and lifting aids to transport and install the unit.
The unit weighs more than 25 kg (
→
Technical Data).
Plan the installation of the filter system. With careful planning, taking the ambient conditions into
account, you will obtain optimum operating results.
The following conditions must be met:
►
As the filter modules are very heavy when filled, they must be placed on a suitable base (at least on
slabs, but preferably on a poured concrete base) to prevent them from subsiding.
►
Plan sufficient space for carrying out cleaning and maintenance work.
►
Drain the dirty water into the drain or far enough away from the pond so that it cannot flow back into
the pond.
−
If the coarse soiling and dirty water both run into the same pipe, it is important to use at least DN
110 pipes.
►
Use a suitable system for removing coarse soiling, e.g. ProfiClear Premium Drum Filter Module.
5.2
Information regarding pipes
►
Use suitable pipes.
►
Do not use any right-angled bends. Bends with a maximum angle of 45° are very efficient.
►
Glue plastic pipes to ensure a permanent and reliable joint or use socket joints with clips to stop
them from coming apart.
►
Standing water in pipes can freeze when there is a hard frost and cause pipes to burst. For this
reason, lay the pipes and hoses with a gradient (50 mm/m) to ensure that they can run empty.
►
For gravity fed systems, it must be possible to shut off the supply from the pond and the return to the
pond for maintenance and repair work. For this reason, install suitable slide valves.
5.3
Installing the filter module and connecting it to additional filter modules
A maximum of three Moving Bed Modules can be installed one after the other.
2.
How to proceed:
G
1. Push the Moving Bed Module container towards the preceding module (Drum Filter Module or other
Moving Bed Module) until the outlet socket of the preceding module slides inside the rubber socket
of the Moving Bed Module up to the stop.
−
The slide valves of the soiled water drains are all located on the same side.
2. Secure the connection with a hose clip.
3. First position the hose clip screw at the top, then tighten. This facilitates later installation steps.
Information about the pump fed system!
If no ProfiClear Premium Individual Module is connected to the last Moving Bed Module, OASE
recommends the following: To ensure an optimum water level in the container fit the ProfiClear Premium
discharge set (Order No.: 50949).
18172-07-13_GA_ProfiClear Premiu23 23
25.07.2013 12:58:55
Summary of Contents for ProfiClear Premium
Page 2: ...2 A ProfiClear0015 B ProfiClea0006 18172 07 13_GA_ProfiClear Premiu2 2 25 07 2013 12 58 52...
Page 3: ...3 C ProfiClear0008 D ProfiClearr007 18172 07 13_GA_ProfiClear Premiu3 3 25 07 2013 12 58 53...
Page 5: ...5 H ProfiClear0039 I ProfiClear0045 18172 07 13_GA_ProfiClear Premiu5 5 25 07 2013 12 58 54...
Page 127: ...127 ProfiClear 0054 18172 07 13_GA_ProfiClear Premiu127 127 25 07 2013 12 58 58...
Page 128: ...128 ProfiClear0055 18172 07 13_GA_ProfiClear Premiu128 128 25 07 2013 12 58 59...
Page 129: ...129 Pro ProfiClear0056 18172 07 13_GA_ProfiClear Premiu129 129 25 07 2013 12 58 59...
Page 130: ...18172 07 13_GA_ProfiClear Premiu130 130 25 07 2013 12 58 59...
Page 131: ...18172 07 13_GA_ProfiClear Premiu131 131 25 07 2013 12 58 59...
Page 132: ...18172 07 13 18172 07 13_GA_ProfiClear Premiu132 132 25 07 2013 12 58 59...