25
- GB -
6 Commissioning/start-up
Two 25 l bags of Hel-X biomedia (50 l) are required for operating a Moving Bed Module. Optionally, 75 l
can be used (supplementary kit Order No.: 51060).
7.
How to proceed:
1. Close the slide valve for the DN 75 dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Fill the container with water:
−
Pump fed system: Switch on the filter pump.
−
Gravity fed system: Open the slide valves (supply and return) of the ProfiClear Premium filter
series to allow the water to flow.
4. Check all pipes, hoses and their connections for leaks.
−
Expansion seals may leak initially until they have fully expanded on contact with water.
5. Fill the container with Hel-X biomedia.
−
Ensure that the Hel-X biomedia can move around freely in the container.
−
It can take several weeks for the Hel-X biomedia to become completely colonised. Uncolonised
Hex-X biomedia tend to float more.
6. Add filter starter BioKick CWS.
7. Fit the container cover.
8. When all filter containers are filled with water, switch on the other electrical units (e.g. filter pumps).
If using filter starters (e.g. OASE BioKick CWS), do not operate any UVC clarifying units for at least
24 hours so as not to disturb the colonisation of the filter media by micro-organisms.
7
Remedy of faults
Malfunction Possible
cause
Remedy
Filter pump not switched on
Switch on the filter pump, connect the power plug
No flow of water
Supply to filter system or return to pond
blocked
Clean the supply and/or return
Bottom drain, pipe or hose blocked
Clean, replace if necessary
Hose kinked
Check hose, and replace if necessary
Water flow insufficient
Excessive loss in lines
Reduce line length to necessary minimum
Insufficient Hel-X biomedia used
Use more Hel-X biomedia if necessary
Water contains too much
ammonium/nitrite
Unit has only been in operation for a short
time
The full biological cleaning effect is only achieved
after several weeks
The meshed tube has slipped
Correct the position of the meshed tube
Hel-X biomedia are being
flushed out
Defective meshed tube
Replace the meshed tube
Aerator rod is blocked
Replace the aerator rod
Less movement of the Hel-
X biomedia
Aerator pump malfunction
Check the aerator pump
Less movement of the new
Hel-X biomedia
Hel-X biomedia are not yet fully colonised
It takes several weeks for the biomedia to become
colonised by bacteria. Wait for the natural process
to take place.
18172-07-13_GA_ProfiClear Premiu25 25
25.07.2013 12:58:55
Summary of Contents for ProfiClear Premium
Page 2: ...2 A ProfiClear0015 B ProfiClea0006 18172 07 13_GA_ProfiClear Premiu2 2 25 07 2013 12 58 52...
Page 3: ...3 C ProfiClear0008 D ProfiClearr007 18172 07 13_GA_ProfiClear Premiu3 3 25 07 2013 12 58 53...
Page 5: ...5 H ProfiClear0039 I ProfiClear0045 18172 07 13_GA_ProfiClear Premiu5 5 25 07 2013 12 58 54...
Page 127: ...127 ProfiClear 0054 18172 07 13_GA_ProfiClear Premiu127 127 25 07 2013 12 58 58...
Page 128: ...128 ProfiClear0055 18172 07 13_GA_ProfiClear Premiu128 128 25 07 2013 12 58 59...
Page 129: ...129 Pro ProfiClear0056 18172 07 13_GA_ProfiClear Premiu129 129 25 07 2013 12 58 59...
Page 130: ...18172 07 13_GA_ProfiClear Premiu130 130 25 07 2013 12 58 59...
Page 131: ...18172 07 13_GA_ProfiClear Premiu131 131 25 07 2013 12 58 59...
Page 132: ...18172 07 13 18172 07 13_GA_ProfiClear Premiu132 132 25 07 2013 12 58 59...