Installation and connection 

Installation planning 

 A 

The illustration shows an example of a lighting system. Variations are possible. 

  Only connect the LED spotlight to components with compatible connections. 

  It is possible to add spotlights to the lighting system if a more powerful switching power pack with additional outputs 

is used. 

  Switching power pack requirements: 

  Electronic switching power pack with DC decoupling between the primary and secondary side. 

  Output voltage: 24 V DC 

  Residual ripple: Max. 5 % 

  Fastening of the LED spotlight: 

 

LED spotlight 

Fastening

ProfiLux LED 110/DMX/02 

To Komet nozzle 10-12 or 10-14 

ProfiPlane LED 110/DMX/02 

In OASE ground installation cup 

ProfiLux LED 320/DMX/02 

With installation bracket to a firm base 

ProfiPlane LED 320/DMX/02 

In OASE ground installation cup 

ProfiLux LED 320/DMX/02 

To Komet nozzle 10-12 or 10-14 

ProfiLux LED Spot 1500/DMX/02 
ProfiLux LED Flood 1500/DMX/02 

With installation bracket to a firm base 

 

 Caption: 

 

 

ProfiLux LED 110/DMX/01 
ProfiPlane LED 110/DMX/01 
ProfiLux LED 320/DMX/01 
ProfiPlane LED 320/DMX/01 

 

ProfiLux LED Spot 1500/DMX/02 
ProfiLux LED Flood 1500/DMX/02 

 

Hybrid extension cable: 
3 m length (50728) 
7.5 m length (56403) 

 

Connection cable 24 V DC: 
1 m length (12762) 
3 m length (12552) 
7.5 m length (12553) 
15 m length (11720) 

 

Connection cable DMX: 
1 m length (12368) 
3 m length (12369) 
10 m length (12372) 
20 m length (12373)) 

 
 

Set-up the unit 

 

 

 

Attention!

 Strong optical radiation from LEDs of the risk group 2. 

Possible consequences:

 Damage to eyes. 

Protective measures:

 

  Do not look into the spotlight directly or for a long time when it is on. 

  Do not direct the spotlight at persons. 

 
 

ProfiLux LED 110/DMX/02 

1.  
0. 

How to proceed: 

 B, C 

Using the mounting clamp, screw the spotlight firmly to the sleeve for Komet 10-12 or Komet 10-14. 

  To ensure optimum fitting, use the Oase sleeve 10 (article number: 51018). 

Loosen the Allen screws on both sides of the spotlight, align the spotlight and tighten both Allen screws. 

 

ProfiPlane LED 110/DMX/02 

1.  
0. 

How to proceed: 

 D, E 

Install OASE the ground installation cup. 
Place the spotlight into the OASE ground installation cup and fasten with three countersunk head screws. 

  When routing the connection cable do not exceed the min. bending radius. 

37744_04-14_GA_ProfiLED_110_320_16   16

11.04.2014   11:53:46

Summary of Contents for ProfiLux LED 110

Page 1: ...ES ProfiLux LED 110 DMX 02 56267 ProfiPlane LED 110 DMX 02 56298 ProfiLux LED 320 DMX 02 50717 ProfiRing LED 320 DMX 02 50718 ProfiPlane LED 320 DMX 02 50719 ProfiLux LED Spot 1500 DMX 02 56388 Profi...

Page 2: ...nd plug DMX Underwater LED Driver DMX 02 DMX Hybrid Connection Box Hybrid Connection Box 24 V DC DMX Underwater LED Driver DMX 02 Underwater Power Supply 250 24V 01 230 V AC 24V DC 24V DC 37744_04 14_...

Page 3: ...3 ProfiLux LED 110 DMX 02 B PLX0010 C D PLX0009 PLX0021 37744_04 14_GA_ProfiLED_110_320_3 3 11 04 2014 11 53 45...

Page 4: ...4 ProfiPlane LED 110 DMX 02 E F PLX0018 PLX0013 ProfiLux LED 320 DMX 02 G H PLX0012 PLX0003 37744_04 14_GA_ProfiLED_110_320_4 4 11 04 2014 11 53 45...

Page 5: ...5 ProfiPlane LED 320 DMX 02 I J PLX0019 PLX0014 ProfiRing LED 320 DMX 02 K L PLX0015 PLX0016 37744_04 14_GA_ProfiLED_110_320_5 5 11 04 2014 11 53 45...

Page 6: ...6 ProfiLux LED Spot 1500 DMX 02 ProfiLux LED Flood 1500 DMX 02 M N PLX0017 PLX0008 O PLX0004 37744_04 14_GA_ProfiLED_110_320_6 6 11 04 2014 11 53 45...

Page 7: ...s Kapitel Lieferumfang Typ Lieferumfang ProfiLux LED 110 DMX 02 LED Scheinwerfer mit Anschlusskabel ProfiPlane LED 110 DMX 02 LED Scheinwerfer mit Anschlusskabel ProfiLux LED 320 DMX 02 LED Scheinwerf...

Page 8: ...hriftsm ige elektrische Installation Elektrische Installationen m ssen den nationalen Errichterbestimmungen entsprechen und d rfen nur von einer Elektrofachkraft vorgenommen werden Eine Person gilt al...

Page 9: ...fiPlane LED 320 DMX 01 ProfiLux LED Spot 1500 DMX 02 ProfiLux LED Flood 1500 DMX 02 Hybrid extension cable 3 m L nge 50728 7 5 m L nge 56403 Verbindungskabel 24 V DC 1 m L nge 12762 3 m L nge 12552 7...

Page 10: ...heinwerfer so drehen dass das Langloch frei zug nglich ist Den Montageb gel am Untergrund befestigen Den Scheinwerfer ausrichten und die Innensechskantschrauben auf beiden Seiten festziehen Scheinwerf...

Page 11: ...lung f r den Scheinwerfer ndern Werte f r die LEDs DMX Adresse und Kon figurationsmodus pr fen LED des Scheinwerfers defekt Scheinwerfer reparieren lassen Leuchtst rke eines Scheinwerfers zu gering LE...

Page 12: ...nterlassene Wartung nicht bestimmungsgem en Gebrauch Besch digung durch Unfall Fall Sto Frosteinwirkung Stecker abschneiden Kabel k rzen Kalkablagerungen oder unsachgem e Reparaturversuche zu r ckzuf...

Page 13: ...bei Betrieb au erhalb des Wassers Produkt im aktiven Zustand 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C Lagerungstemperatur Produkt im inaktiven Zustand strom los 20 C 70 C 20 C 7...

Page 14: ...very Type Scope of delivery ProfiLux LED 110 DMX 02 LED spotlight with connection cable ProfiPlane LED 110 DMX 02 LED spotlight with connection cable ProfiLux LED 320 DMX 02 LED spotlight with connect...

Page 15: ...ct electrical installation Electrical installations must meet the national regulations and may only be carried out by a qualified electrician A person is regarded as a qualified electrician if due to...

Page 16: ...DMX 01 ProfiPlane LED 320 DMX 01 ProfiLux LED Spot 1500 DMX 02 ProfiLux LED Flood 1500 DMX 02 Hybrid extension cable 3 m length 50728 7 5 m length 56403 Connection cable 24 V DC 1 m length 12762 3 m l...

Page 17: ...light to allow access to the slot of the installation bracket Fasten the installation bracket to the ground base Align the spotlight and tighten the Allen screws on both sides Connecting the spotlight...

Page 18: ...setting Change the spotlight setting Check the values for the LEDs DMX add ress and configuration mode LED of the spotlight defective Have spotlight repaired Luminous intensity of a spotlight is insuf...

Page 19: ...able cleaning materials or negligent maintenance use other than that intended damage due to accidents falls impact effect of frost cutting plugs shortening cables calcium deposits or improper attempt...

Page 20: ...operation outside the water product active 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C Storage temperature product inactive disconnected from the power supply 20 C 70 C 20 C 70 C 20...

Page 21: ...section Pi ces faisant partie de la livraison Type Fourniture ProfiLux LED 110 DMX 02 Projecteur DEL avec c ble de raccordement ProfiPlane LED 110 DMX 02 Projecteur DEL avec c ble de raccordement Prof...

Page 22: ...ns lectriques doivent r pondre aux r glements d installation nationaux et leur ex cution est exclusi vement r serv e un technicien lectricien Une personne est consid r e comme technicien lectricien lo...

Page 23: ...320 DMX 01 ProfiPlane LED 320 DMX 01 ProfiLux LED Spot 1500 DMX 02 ProfiLux LED Flood 1500 DMX 02 C ble d extension hybride 3 m de long 50728 7 5 m de long 56403 C ble de raccordement 24 V CC 1 m de l...

Page 24: ...le trou oblong soit accessible Fixer l trier de montage au fond Aligner le projecteur et resserrer les deux vis six pans creux de part et d autre Raccorder le projecteur Remarque Ne pas d passer la p...

Page 25: ...les DEL l adresse DMX et le mode de configuration La DEL du projecteur est d fectueuse Faire r parer le projecteur Intensit lumineuse trop faible pour un projec teur Lumi re des DEL du projecteur exce...

Page 26: ...une utilisation non conforme la finalit un endommagement d un accident une chute un impact aux effets du gel des sectionnements de prise des raccourcissements de c ble des d p ts calcaires ou des tent...

Page 27: ...missible lors d une utilisation hors de l eau pro duit activ 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C 4 C 35 C Temp rature d entreposage produit inactiv sans courant 20 C 70 C 20 C 70 C 2...

Page 28: ...inistro ProfiLux LED 110 DMX 02 Proyector de luz LED con cable de conexi n ProfiPlane LED 110 DMX 02 Proyector de luz LED con cable de conexi n ProfiLux LED 320 DMX 02 Proyector de luz LED con cable d...

Page 29: ...a conforme a lo prescrito Las instalaciones el ctricas deben cumplir las prescripciones de montaje nacionales y se deben realizar s lo por un electricista calificado Una persona es un electricista cal...

Page 30: ...pot 1500 DMX 02 ProfiLux LED Flood 1500 DMX 02 Cable de extensi n de fibra h brida 3 m de longitud 50728 7 5 m de longitud 56403 Cable de conexi n de 24 V CC 1 m de longitud 12762 3 m de longitud 1255...

Page 31: ...luz y gire el proyector de luz de forma que el agujero longitudinal est libremente accesible Fije el soporte de montaje en la base Alinee el proyector de luz y apriete los tornillos de cabeza con hex...

Page 32: ...el ajuste para el proyector de luz Compruebe los valores para los LEDs la di recci n DMX y el modo de configuraci n LED del proyector de luz defectuoso Encargue la reparaci n del proyector de luz Muy...

Page 33: ...limpiadores inapropiados por no ejecutar los trabajos de mantenimiento un uso no conforme a lo prescrito da os por accidente ca da golpe heladas el corte de las clavijas de enchufe la reducci n de la...

Page 34: ...le del entorno en caso de operaci n fuera del agua producto en estado activo 4 C a 35 C 4 C a 35 C 4 C a 35 C 4 C a 35 C 4 C a 35 C 4 C a 35 C 4 C a 35 C Temperatura de almacenamiento producto en esta...

Page 35: ...0 3 0 6 mg l 0 3 mg l Chloridgehalt Chloride concentration Teneur en chlorure Contenido de cloruro 250 mg l 200 mg l 22000 mg l Salzgehalt Salinity Teneur en sel Contenido de sal 4 0 Gesamttrockenr ck...

Page 36: ...37744 04 14 OASE GmbH www oase livingwater com Tecklenburger Stra e 161 48477 H rstel Germany 37744_04 14_GA_ProfiLED_110_320_36 36 11 04 2014 11 53 46...

Reviews: