background image

ProMax MudDrain 7000  |  11000  |  14000

Summary of Contents for promax cleardrain 14000

Page 1: ...ProMax MudDrain 7000 11000 14000 ...

Page 2: ...2 ProMax MudDrain 7000 11000 14000 A POX0008 B POX0013 C D POX0010 POX0011 ...

Page 3: ... 3 E POX0009 ...

Page 4: ... Additional information A Reference to a figure e g Fig A Reference to another section PRODUCT DESCRIPTION Overview A ProMax Mud Drain 7000 11000 14000 1 Handle adjustable 2 Pump base 3 Float switch 4 Connection pressure side G1 5 Power connection cable 6 Stepped hose adapter Intended use ProMax MudDrain 7000 11000 14000 re ferred to in the following as unit may only be used as specified in the fo...

Page 5: ...e Only plug the unit into a correctly fitted socket Safe operation Dangerous electrical voltage Possible death or severe injury from electrocu tion Before reaching into the water al ways switch off and disconnect isolate all units located in the water with a volt age of 12 V AC or 30 V DC and se cure them from being switched on again Only operate the unit if no persons are in the water Never opera...

Page 6: ...s function ensure that the length of cable between the float switch and the cable clip measures at least 10 cm N O T E The minimum residual water height is only reached in manual mode Manual mode The pump remains permanently switched on if the float switch is set vertically and the cable points downward N O T E The pump can run dry in manual mode Switch off the pump when the minimum water level is...

Page 7: ...se this will impair the operat ing life of the unit accordingly N O T E Rinse the pump with clean water after use REMEDY OF FAULTS Malfunction Cause Remedy Pump does not start Power supply interrupted Check the fuse and electri cal plug connections Pump switches off after a short running period Overload protection has switched the pump off due to overheating Clean the intake and pressure hose Allo...

Page 8: ...and chlorine free household cleaning agent After cleaning thoroughly rinse all parts in clean water WEAR PARTS Wear parts are excluded from the war ranty The following components are wear parts and may only be replaced by the OASE Service Impeller STORAGE OVER WINTERING The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store ...

Page 9: ...tion pressure side G1 G1 G1 Minimum switch on height maximum switch off height mm 500 250 530 270 530 270 Maximum switch on height minimum switch off height mm 670 120 700 100 700 100 Flow rate max l h 7500 11500 14500 Head height max m 5 7 11 Immersion depth max m 7 7 7 Particle size max mm 30 30 30 Power connection cable Length m 10 10 10 Dimensions Length mm 193 193 193 Width mm 247 247 247 Hei...

Page 10: ...POX0039 ...

Reviews: