POS 

 

     

Benennung 

Kunststoff- Entlüfter                                          Plastic air bleeder 

Druckmanometer                                            

Pressure Gauge 

Adapter aus Messing                              

T- Assembly (complete) 

Acryl- Kuppel                                            

Closure 8 ½ " transparent 

O-Ring für Kuppel                                        

O-ring closure 8 ½ " 

Entlüftungssieb                                              

Air Relief Tube Strainer 

Oberer Verteiler – Diffuser                                Diffusor for filter 

Obere Verrohrung zum Diffuser                         Top Piping Assembly for filter 

Entlüftungsröhrchen                                        

Air Relief Tube for filter 

10 

Anschlussverschr. Für Entlüftung                     Male Connector Air Relief Tube 

11 

Untere Verrohrung zum Verteiler                   

Lower Piping Assembly for filter 

12 

Düsenstern ohne Schlitzrohr                        

 

Hub threaded for filter

 

13 

Schlitzröhrchen                                           

Lateral for filter 

14 

Entleerungsventil                                         

Drain ( complete 

15 

Schlüssel für Kuppel                                   

 

Wrench 8 ½ " for closure

 

16 

Innere Sicherungsmutter 2" a                     

Internal Locknut 2" PVC 

17 

Innere konischer Zwischenring                   

Internal Spacer 2" PVC 

18 

Innerer O-Ring für Durchführung                 

O-ring 2" Bulkhead 

19 

Äußerer konischer Zwischenring                  

External Spacer 2" PVC 

20 

Durchführungsfitting 2"                                 

2" Bulkhead fitting PVC 

21 

Äußere Flachdichtung 2" f. Durchführung   

Flat gasket 2" for bulkhead fitting 

22 

Fuß                                                                 

Tankbase for filter 

23 

Verrohrtes 6-Wege-Ventil                                  Manual multi-port valve 

Summary of Contents for QSF 485/4/10

Page 1: ...nting instructions f r for OASE Kristall Quarzsandfilteranlage OASE Quartz Sand Filter System QSF 485 4 10 Mat Nr 53075 QSF 610 9 10 Mat Nr 53072 QSF 762 13 10 Mat Nr 53073 OASE GmbH Postfach 2069 484...

Page 2: ...ASE Kristall Quarzsandfilteranlage OASE Quartz Sand Filter System QSF 485 4 10 QSF 610 9 10 QSF 762 13 10 Druckstutzen pressure socket Saugstutzen intake socket Vorfilter preliminary filter Pumpe pump...

Page 3: ...Norm Betriebsdruck stand operating pressure bar 0 4 0 8 0 4 0 8 0 4 0 8 Max Temperatur max operating temperature C 45 45 45 Dauer der R cksp lung ca time of backwash approx min 2 3 2 3 3 4 Typ Mat Nr...

Page 4: ...peration of water display systems As incontestable function of a Fountain Pump System including all components is very much dependent on quality of waters For this the operator is responsible The max...

Page 5: ...fest und eben sein Montieren Sie Druckmanometer und Entl ftungsventil an die Acryl Kuppel 1 5 Mounting The filter unit has to be mounted so that maintenance works are possible placed in a dry Install...

Page 6: ...switch valve handle while pump is running Filter operation Procedure in short version see attached table under A 1 A 5 To clean backwash the filter At normal operation conditions the operation pressu...

Page 7: ...f Tube 11 Untere Verrohrung zum Verteiler Lower Piping Assembly for filter 12 D senstern ohne Schlitzrohr Hub threaded for filter 13 Schlitzr hrchen Lateral for filter 14 Entleerungsventil Drain compl...

Page 8: ...in die gew nschte Position gebracht Achtung NIEMALS die POSITON des Ventilhebels bei LAUFENDER PUMPE verstellen Attention In case of order please mention filter type 6 way backwash valve The multiport...

Page 9: ...L sen und Oberteil abnehmen Ventil Innenteile reinigen und aussp len Wenn erforderlich Deckeldichtung erneuern Bei Zusammenbau auf Positionsmarkierung achten Nocke und Kante bereinander liegend Valve...

Page 10: ...g Bei Montage und Inbetriebnahme der EUROTRONIK 10 Steuerung unbedingt die erweiterte Bedienungsanleitung beachten Valve Automatic Eurotronik 10 Fully automatically backwash control with 2 channel tim...

Page 11: ...25kg 6 Sack a 25kg 11 Sack a 25kg Max Betriebstemperatur Max working temperature 50 C 50 C 50 C Max Betriebsdruck Max working pressure 3 5 bar 3 5 bar 3 5 bar Saugleitungs Anschluss Connection suction...

Page 12: ......

Reviews: