- GB -
17
Remedy of faults
Malfunction Cause
Remedy
Disconnect the unit from the voltage supply for at least
5 minutes
No voltage supply or malfunction in DMX line
Check all lines and connections
Unsuitable DMX channel or mode selected
−
Correct DMX channel settings (
→
Addressing via
DMX)
−
Correct Personality ID settings (
→
Addressing via
DMX-RDM)
−
Check starting address and DMX value
No connected 24-V-DC product is
controlled
Unit, DMX controller or switching power pack
defective
Determine which unit is defective and proceed with the
malfunction remedy according to its instruction manual
Unsuitable DMX channel or mode selected
−
Correct DMX channel settings (
→
Addressing via
DMX)
−
Correct Personality ID settings (
→
Addressing via
DMX-RDM)
−
Check starting address and DMX value
One or more connected 24-V-DC
products are not accessed proper-
ly
Unit output defective
Have unit repaired
Repair
The unit can only be repaired by
OASE
. Please send the unit to your
OASE
dealer.
Maintenance and cleaning
If necessary, clean the unit with clear water using a soft brush.
Storage/Over-wintering
In case of extreme frost or ice loading, deinstall the unit(
→
Technical data). Thoroughly clean and check the unit for
damage.
Disposal
Dispose of the unit in accordance with the national legal regulations.
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
30539-10-13_GA_Underwater Switch17 17
29.10.2013 10:16:30
Summary of Contents for Underwater Switch 24V DC/DMX/02
Page 2: ...2 A UWR0001 B UWR0004 30539 10 13_GA_Underwater Switch2 2 29 10 2013 10 16 30...
Page 3: ...3 C D UWR0002 UWR0003 E PLX0004 30539 10 13_GA_Underwater Switch3 3 29 10 2013 10 16 30...
Page 37: ...37 UWR0006 30539 10 13_GA_Underwater Switch37 37 29 10 2013 10 16 31...
Page 38: ...30539 10 13_GA_Underwater Switch38 38 29 10 2013 10 16 31...
Page 39: ...30539 10 13_GA_Underwater Switch39 39 29 10 2013 10 16 31...