- EN -
20
Addressing via DMX/RDM
RDM (Remote Device Management) is an open and bi-directional protocol standard for DMX-controlled devices. The
permanently transmitted DMX data flow briefly pauses (several milliseconds), and an RDM data package (message) is
sent directly to a subscriber. The subscriber evaluates the information in the data package and sends an answer (semi-
duplex) on the same line. Targeted polling to a subscriber via its UID (Unique ID) prevents several subscribers from
answering simultaneously.
The protocol makes it possible to receive status information about a unit or to change configurations on a unit. Chang-
ing the configuration means, e.g. changing the DMX address. The prerequisite for this function is a RDM-compatible
controller. Read the corresponding operating instructions
RDM parameters
General parameters
GET
CMD
SET
CMD
Description
STATUS_MESSAGES
•
Used to manage status messages
STATUS_ID_DESCRIPTION
•
SUPPORTED_PARAMETERS
•
Overview of all RDM parameters
PARAMETER_DESCRIPTION
•
Description of all parameters
DEVICE_INFO
•
Brief overview of the most important features
DEVICE_MODEL_DESCRIPTION
•
Type designation
MANUFACTURER_LABEL
•
Manufacturer's designation
DEVICE_LABEL
•
•
Labelling field
SOFTWARE_VERSION_LABEL
•
Firmware version number
DMX_START_ADDRESS
•
•
Reading and setting the DMX start address
SENSOR_DEFINITION
•
Sensor information
SENSOR_VALUE
•
•
Sensor values
Sensor 1 TempErrCount
Temperature error counter
Sensor 2 MotorFailureCount
Motor failure counter
Sensor 3 ActualSpeed
Current actual speed
Sensor 4 NominalSpeed
Current set point speed
Sensor 5 PWM
Current PWM value
Sensor 6 Temp
Current operating temperature
Sensor 7 PowerVoltage
Current voltage
Sensor 8 CurrentConsemption Current current consumption
IDENTIFY_DEVICE
•
•
0 =
Normal operation
1 =
The pump will switch on and off again at short intervals. This function is helpful
for identifying the device in the field.
DEVICE_HOURS
•
Operating hour counter, total
DEVICE_POWER_CYCLES
•
Counter for cold startup/switch-on
RESET_DEVICE
•
Executes a reset
1 =
Warm start
255 =
Cold start
Specific parameters
GET
CMD
SET
CMD
Description
Curve X1
•
Support value 1 of the stored pump characteristic curve
Curve Y1
•
Curve X2
•
Support value 2 of the stored pump characteristic curve
Curve Y2
•
Curve X3
•
Support value 3 of the stored pump characteristic curve
Curve Y3
•
Runtime hours
•
Operating hour counter for the running period
Startup counter
•
Startup counter
Config mode
•
Only for service purposes