- GB -
12 Digital
inputs
The unit is equipped with eight configurable, galvanically isolated inputs for connection with third-party
systems or sensors.
The input voltage range for the digital inputs is between min. -5V and 30V DC
(Low=-5V..5V, High= 11V..30V).
In addition that the digital input terminal (GND) must be activated (see figure).
Alternatively, the digital input 1 can be used to connect an OASE anemometer (No. 53913).
Wind speed measuring is useful for controlling the height of outdoor fountains used outside in relation to
the wind speed. In order to use the function the “speed”-canals of the pumps must be linked with the wind
fader in the WEPS-software. See also chapter 19.
Anemometer
53913
22188-10-14_GA_WECS II-512-1024-32 32
06.10.2014 12:53:00
32