- GB -
Hauptmenü
Untermenü 1
Untermenü 2
Untermenü 3
Beschreibung
7. Master
Grandmaster Set
Grandmaster
Show the grandmaster in percent. The value
can be adjusted by using the CURSOR keys
[0..100]%.
Windmaster 1..3
Show the selected wind master in percent.
The value will be updated by the wind
speed.
Basic Value 1
Edit Value 1
Show the interpolation value No.1 of the
characteristic curve.
Basic Value 2
Edit Value 2
Show the interpolation value No.2 of the
characteristic curve.
Basic Value 3
Edit Value 3
Show the interpolation value No.3 of the
characteristic curve.
Ramp Down
Edit Ramp Down
Fading down speed in percent per second of
the windmaster.
Ramp Up
Edit Ramp Up
Fading up speed in percent per second of
the windmaster.
Waiting Time
Up
Edit wait time
Waiting time in seconds before the
windmaster is fading up after fading down.
Submaster 1 .. 4
…
Set Submaster
1..4
Show the submaster in percent. The value
can be adjusted by using the CURSOR keys
[0..100]%.
8. Setup
The menu Setup contains all important
configuration parameters and information.
Caption Edit
Caption
The caption label can be changed according
to the project. The text will be shown at the
WEPS software.
Universe DMX1
Select
Universe
The DMX ports can be linked to Universe 1
or Universe 2.
Universe DMX2
RDM Mode
DMX1
RDM Mode
DMX2
Enable RDM
DMX1(2)
The RDM function can be switched on or off
for each DMX port.
Digital Outputs
DO 1 Patch
DO 2 Patch
…
Edit Patch
Each digital output can be linked to a DMX
Universe and address.
DO 1 Mode
DO 2 Mode
…
Change Mode
[Standard
/Remanent]
Each digital output can be operated either in
Standard or in Remnant mode.
Date Edit
Date
Shows and edits the current date in format:
JJJJ-MM-DD.
Time (UTC)
Edit Time
(UTC)
Shows the current time as „coordinated
universal time“ UTC.
Timezone Select
Timezone
Shows the current time zone. The time zone
can be selected from UTC (coordinated
universal time) and CET (Central European
Time, UTC+1) with daylight-saving time.
CET is the recommended choice.
IP-Address Edit
IP
Shows and edits the IP-Address. Default
setting:
192.168.003.011
Subnet-Mask Edit
IP-Mask
Shows edit the subnet-IP mask. Default
setting:
255.255.255.000
Software Version
Shows the software version label.
MAC-Address
Shows the network MAC address.
OS-Version
Shows the current operating system label.
Licence Info
Shows the location of the GPL and
copyrights.
18.1 Starting
Now connect the device with a 15-24 V power supply. Re-starting the unit takes approx. 20 seconds. After
that the LCD screen displays the main mask of the operating/control system (
WECS II 512/time
or
WECS
II 1024/time
). If the unit cannot be restarted correctly at this point, please check the voltage supply and
ensure that all connections are tightly fixed.
22188-10-14_GA_WECS II-512-1024-36 36
06.10.2014 12:53:00
36
Summary of Contents for WECS II 512 DMX/02
Page 6: ... DE 4 Abmessungen 22188 10 14_GA_WECS II 512 1024 6 6 06 10 2014 12 52 58 6 ...
Page 27: ...27 GB 4 Dimensions 22188 10 14_GA_WECS II 512 1024 27 27 06 10 2014 12 52 59 ...
Page 48: ... FR 4 Dimensions 22188 10 14_GA_WECS II 512 1024 48 48 06 10 2014 12 53 00 48 ...
Page 69: ...69 ES 4 Dimensiones 22188 10 14_GA_WECS II 512 1024 69 69 06 10 2014 12 53 01 ...