CX Chlorinator - Salt and Mineral Operation MANUAL
Page
8
of
33
4.3 Installation Diagram
WARNING:
DO NOT
plug in if carton has been wet
Important
Notes:
The pump rating must not exceed 8amps.
Saltwater may damage electrical components in the Power Pack.
WARNING:
We
DO NOT
recommend the use of valves on the inlet or outlet of the cell housing. If you do use a
valve, then it is important to ensure that the valve cannot deadhead (lock closed) while the pump is
running. It is the installers responsibility to ensure some form of flow control is installed in this instance,
and it disables the pump.
ALWAYS
ensure that pipe work and equipment
DO NOT
allow gases generated from the cell to collect
and build up in any part of the installation.
It is
RECOMMENDED
that the Cell Housing be installed horizontally to create a natural gas trap that
acts as a safety device. Installation in any other way may cause explosion, injury or death if the installer
does not allow for gas removal. A venturi pipe is installed/moulded within the Cell Housing design to
eliminate any possible gas build up, although it is always recommended to ensure proper installation to
eliminate this from happening.
The Cell Housing must be installed in the
RETURN
pipework to the pool. It must always be installed
after the filter, gas heater, solar heating, or heat pump.
DO NOT
apply priming fluid to the cell Housing, it is not needed and may react with the plastic.