7.

 

To install the carbon filtration system, cut the blue tube which is looped in the filter compartment.  Cut it so you have 
enough tubing to connect your filter inlet and outlet without making the tubes too tight. 

8.

 

Connect your filters and turn on water to flush filter(s) per the manufacturer’s instructions. 

9.

 

Check for leaks.  The filters are after the reservoir float valve, so if no water flows, make sure the safety float hasn’t 
tripped. 

REVERSE OSMOSIS FILTRATION INSTALLATION

 

10.

 

Connect your brine line, with flow restrictor, to the elbow on the purple (alternatively red) tubing. 

11.

 

If your supply water has a lot of sediment, you may wish to put a sediment filter before the reservoir float valve.  To do 
so, cut the white tubing and connect your filter in-line. 

12.

 

Depending on your system, any pre-carbon filter can be placed in-line on the white tube or the blue.  The RO membrane 
must be connected to the blue tubing to work properly.  The post carbon would also be on that line (see figure 4).  

 

Follow these steps when first using your water cooler and during normal maintenance operations: 

IMPORTANT:  Do not 

plug in the cooler until you have filled the reservoir.

 

1.

 

Upon taking your cooler out of the box, follow the steps in the section titled “CLEANING YOUR WATER 
RESERVOIR" on page 9.  The baffle is shipped in a bag located in the filter compartment.  Install it in the reservoir 
after cleaning the reservoir and baffle.  Your last step during this first cleaning will be step 21, “Put the side panel back 
on, then place the cabinet top on and tighten the screws so they are snug.”  After you clean and rinse the cooler, you are 
ready to connect it to your water supply.  NOTE:  If you have a leak controller installed on the unit, the water supply 
line should be connected directly to it.  This will shut the water off as close to the water supply valve as possible in the 
event of a water leak in the cooler. 

2.

 

If you wish to install a filter in the cooler, see the section labeled “FILTER INSTALLATION” starting on page 4. 

3.

 

Turn on water supply to the cooler. 

4.

 

Check to see that water flows easily from all taps (see hot water safety instructions on page 2).  

IMPORTANT:  You 

must wait until water has filled the hot tank before plugging in the cooler to avoid overheating.

  You can check for 

this by pressing the hot water dispense button until water flows out of the spout. 

5.

 

As the cooler fills, check for leaks. 

6.

 

Plug the cooler into an outlet that is properly installed and grounded. 

The POU2LR cooler does not have an LCD display so it uses mechanical controls for the heating and cooling of the water.  
You can access the cold control and hot tank switch through the column support after the door is removed.  See the section on 
servicing the cooler on page 11 for directions on removing the door, getting to the cold control to replace it, etc.  Set the cold 
control where you want it by using a small bladed screwdriver to rotate the thermostat knob.  Turn the knob clockwise for 
colder water, and counter-clockwise for less cold.  The factory setting is in the full cold position.  The hot tank does not have 
an adjustable control. 

Note:  The rest of this first use section only applies to coolers with an LCD display. 

1.

 

Upon plugging the cooler in, nothing is displayed on the control panel.  The hot tank and the compressor are not 
operating. 

2.

 

Press the “POWER” button on the cooler display (see figure 5), the clock will flash 12:00 AM. 

FIRST USE 

Figure 4 

Summary of Contents for Aquabar 2

Page 1: ...the LCD display 5 Setting the Clock 6 Setting hot and cold temperature 6 Setting Energy Saver mode 6 Setting filter life monitor 7 Setting UV bulb life monitor 7 Hot booster mode 8 Locking the displa...

Page 2: ...of gallons is programmed through the display panel on the front of the unit which is detailed on page 7 No message will be displayed until the accumulated number of gallons reaches approximately 90 o...

Page 3: ...y by calling customer service at 614 861 1350 Electrical Power Requirements see data plate on base Tri temp models 115v 60 Hz 4 9A 230v 50 Hz 2 5A Duo temp model 115v 60 Hz 1 2A 230v 50 Hz 0 6A CAUTIO...

Page 4: ...functions properly 1 Make sure water is turned off and line is not under pressure 2 Remove door by lifting out drip tray and pressing door latch down forcing the top of the door to lean outward The r...

Page 5: ...are ready to connect it to your water supply NOTE If you have a leak controller installed on the unit the water supply line should be connected directly to it This will shut the water off as close to...

Page 6: ...LAKE 12 Press or button to set the cold water temperature from OFF to COLD about 50 F to COLDER about 45 F to COLDEST about 40 F NOTE Each time the button is pushed the temperature display advances an...

Page 7: ...tank Example END TIME 6 00 AM When the ENERGY SAVER mode is activated the cold tank and the hot tank will turn back ON at 6 00 AM and normal energy consumption will resume cooling the cold tank and he...

Page 8: ...o the cooler To engage the lock press and hold the and buttons at the same time for 3 seconds After 3 seconds you will hear a single beep and the word LOCKED will be displayed above the cup icon Once...

Page 9: ...the reservoir will not drain out 9 In a clean container prepare a solution of 2 teaspoons 10ml of mild dish soap in 2 gallons 8 liters of clean room temperature water 10 Wash the baffle and lids compl...

Page 10: ...refully pour the 2 gallon solution into the reservoir 5 Let the sanitizing solutions sit for 5 minutes no more than 10 minutes Wipe down the exposed inner surface of the reservoir using the solution i...

Page 11: ...e of the metal base before trying to slide it down The front ear has a notch to slide over a raised area in the plastic base see figure 7 TO REMOVE THE FAUCET MANIFOLD The center front panel under the...

Page 12: ...air is required Follow the sequence of steps listed below to avoid damaging the plastic base in the repair process 1 Drain all water from the unit This will make the unit easier to handle 2 Remove the...

Page 13: ...heat or cool the thermostat may be broken Call customer service Water cooler is noisy The water cooler is equipped with a refrigeration system It is normal to hear a refrigerator like vibrating sound...

Page 14: ...ries Low Battery first warning Green Or Red after 3 days beeping max Flashing or Off a 2 flashes On or Off a 2 beeps Dry Examine the sensor hold button until LED light stays solid to stop alarm turn k...

Page 15: ...e the cost of labor required to disconnect and reconnect plumbing and electrical connections or the labor to remove the refrigeration system from the water cooler will be the responsibility of the use...

Page 16: ...OASIS INTERNATIONAL 222 E Campus View Blvd Columbus OH 43235 U S A 1 800 64 OASIS 1 800 646 2747 www OasisCoolers com Printed in China 2010 OASIS International 031666 019 rev B...

Page 17: ...he silicone plug from it as well then place baffle into reservoir 5 Gently place the UV bulb into the hole in the SS lid 6 Thread it in turn clockwise until it is snug You can lift the black float lid...

Page 18: ...hangs up lift it a little higher or let it drop slightly Panel should come free easily 10 Carefully cut zip tie off of bundled wires inside compressor area Don t cut through wire insulation 11 Insert...

Page 19: ...through hole at back of shelf into the reservoir area 17 Connect wire harness The 4 pin housings only connect one way UV bulb install in Aquabar 2 Note For POU2LR model plug unit in and make sure comp...

Page 20: ...installed the black cabinet top will be almost flush with the area around the circuit board Start Fingers OASIS INTERNATIONAL 222 East Campus View Blvd Columbus OH 43235 U S A 1 800 950 3226 www oasis...

Reviews: