7
14.
Use the (+) button to move forward from weekdays to Saturday/Sunday and the (-) button to move back to the
weekdays. It does not roll over from Saturday/Sunday to Monday through Friday. NOTE: The beginning and
ending time for weekdays and weekends must be set individually. This means the procedure must be repeated two
times to set the energy saver schedule for weekends and weekdays.
15.
Press the “ENERGY SET” button again, and the hour on the clock will flash and the word “BEGIN” lights up.
16.
Press (+) or (-) button to set the hour that you want the ENERGY SAVER mode to begin (such as at 10:30 PM in
the example above).
17.
Press “ENERGY SET” again and the minutes will flash.
18.
Press (+) or (-) button to set the minutes.
19.
Press the “ENERGY SET” button again and the hour on the clock flashes and the word “END” lights up.
20.
Press (+) or (-) button to set the hour that you want the ENERGY SAVER mode to end (such as at 6 AM in the
example above).
21.
Press “ENERGY SET” again and the minutes flash.
22.
Press (+) or (-) button to set the minutes. Press “ENERGY SET” again and it will exit the set mode. Or, after 10
seconds of no action, it will exit the mode and return to the regular time display screen. “ENERGY SAVER” times
are now set but the mode is not activated. After setting the weekday schedule, repeat steps 13 through 22 to set the
weekend schedule.
23.
To activate the “ENERGY SAVER” mode, push the “ENERGY SAVER” button. The words “ENERGY SAVER”
will light up on the screen.
ENERGY SAVER MODE
Example
– BEGIN TIME 10:30 PM
•
When the “ENERGY SAVER” mode is activated, the cold tank and the hot tank will turn OFF at 10:30 PM and no
energy will be used during the night to cool the cold tank or heat the hot tank.
Example
– END TIME 6:00 AM
•
When the “ENERGY SAVER” mode is activated, the cold tank and the hot tank will turn back ON at 6:00 AM and
normal energy consumption will resume cooling the cold tank and heating the hot tank.
NOTE: Models with a UV light installed will continue to have UV protection inside the reservoir when the energy saver
mode is on.
SETTING THE FILTER LIFE MONITOR
The filter life monitor is factory set at 0 gallons which means the feature is turned off. If you wish to reset the filter life
monitor or set it for the first time, use the following steps.
24.
With the cooler plugged in, the display should be off. If it is not, press the “POWER” button to turn it off.
25.
Hold down the (+) button and press the “POWER” button at the same time. You will hear a beep and enter the
filter life monitor mode.
26.
Use the (+) or (-) button to set the total number of gallons you wish to monitor to. The display counts in multiples
of 10. Hold down the (+) or (-) button to roll through the numbers. The maximum number of gallons you can enter
is 1200 and it does not roll over to 0 after this value.
27.
Press the “POWER” button again to set this gallon count in memory.
28.
To turn the cooler back on, press the “POWER” button one more time. This process is also how you reset the
gallon counter once the previous gallon count has been reached.
SETTING THE UV BULB MONITOR
The cooler is equipped with a month timer to track when to replace the UV bulb if you are using one. The factory setting is 0
months. If you wish to set the UV bulb monitor, use the following steps.
29.
With the cooler plugged in, the display should be off. If it is not, press the “POWER” button to turn it off.
30.
Hold down the “HOT BOOSTER” button and press the “POWER” button at the same time. You will hear a beep
and enter the UV bulb life monitor set up mode. The word “BULB” will be displayed along with two digits.