background image

6

Water Supply and Drain Connections

Refer to, and follow, the assembly and 

installation instructions provided with the 

supply valves and drain system. Carefully 

check all connections for leaks. 

Finishing Guidelines

Filler strips or filler material may be required 

over the framing to ensure the under lay-

ment mounts flush over the nailing flanges. 

A water resistant under layment is recom-

mended surrounding the unit. Stop the 

under layment 1/16 to 1/8-inch from the unit 

surface, and fill the space with a continuous 

bead of water resistant sealant. (Illust. 6)

NOTE: Oasis recommends a high qual-

ity silicone based sealant with a mold and 

mildew resistant content.

Use care when fastening the under layment 

near the unit surface to avoid damage. Seal 

the under layment seams and edges, as 

required, and install the finish material to 

specifications. 

UNIT SURFACE CARE

WARNING!

NEVER USE ABRASIVE MATERIALS,

OR ABRASIVE CLEANERS

ON THE UNIT SURFACE!

EXTREME CAUTION is urged regarding  

the use of any cleaner, acid or solvent 

on the unit surface. 

 

READ AND FOLLOW PACKAGE 

INSTRUCTIONS FOR ALL 

PURCHASED CLEANING PRODUCTS!

Through routine use, the unit surface can 

collect residues from soap, bath additives 

and natural body oils. Additional deposits 

can also collect from minerals or particles 

found in the water. After each use, wipe the 

excess water from the unit.This practice 

will reduce the buildup of deposits and help 

maintain the natural unit lustre.

Following a thorough surface cleaning, 

an application of quality automotive wax 

will help reduce major accumulations. The 

actual schedule for cleaning and waxing will 

depend on unit usage and water quality.

WARNING!

NEVER APPLY WAX

TO THE UNIT FLOOR!

u

  Routine Cleaning: Mild, non-abrasive 

cleaner specifically formulated for gelcoat 

and acrylic surfaces recommended. (Rinse 

surface thoroughly)

u

  Heavy Soap Deposits: Liquid ammonia 

household cleaner, applied full strength. 

(Rinse surface thoroughly)

u

  Stubborn Stains: Liquid household 

cleaner or hydrogen peroxide applied 

full strength. Place a saturated clean rag 

directly on stain and let stand several hours. 

(Rinse surface thoroughly)

u

  Hard Water Scales: Liquid scale remover 

or white vinegar, applied full strength. 

(Rinse surface thoroughly)

u

  Mold/Mildew: Liquid mildew remover or 

baking soda and water paste. (Apply paste 

and allow to fizz several minutes.) (Rinse 

surface thoroughly)

u

  Construction Adhesive: Soften adhesive 

with a hand held hair dryer and peel off 

adhesive. (Caution is advised when using 

any electrical device near water.)

For adhesive residue, apply rubbing alcohol 

or nail polish remover, full strength. (Rinse 

surface thoroughly)

WARNING!

BATH MATS AND OTHER ITEMS 

HELD IN PLACE USING SUCTIONS

MUST BE REMOVED FROM THE UNIT 

SURFACE AFTER EACH USE.

OVER AN EXTENDED PERIOD

FAILURE TO REMOVE 

SUCTION ATTACHED ITEMS WILL 

DAMAGE THE UNIT SURFACE.

Illustration 3 - 

Unit Installation

Procedure

Nailing

Flange

Wall 

Framing

2. Level Tub
in Framed Area.

Whirlpool Access

Confirm unit is square

within the framed area.

Nailing Flange

Confirm the tub is level

along the sides and 

across each end.

Illustration 3 - 

Unit Installation

Procedure

Nailing Flange

Wall Framing

Drill 1/8 inch hole through

flange at each framing member

Illustration 4 - Securing Unit

Wall

Framing

Secure unit to

framing with

large headed

fasteners.

CAUTION: Protect unit surface

with a shield when fastening.

Nailing Flange

Illustration 5 - Securing Unit

Summary of Contents for BA-5429

Page 1: ...room drain location l Check unit for surface damage l Check unit color for coordination to other bathroom fixtures Whirlpool System Check Assembly and operational instructions are included in a separate publication for all whirlpool and air equipped models l Check for proper trim color and system options INSTALLATION SITE FRAMING Due to individual site variations exact guidelines for every situati...

Page 2: ... flange at each framing member to maintain the unit in the proper position With the unit square and level in the alcove drill a 1 8 hole throught the nailing flange at each framing member Secure the unit in place across the back wall first followed BA R 41 L illustrated BA R 51 L illustrated 2 Dia Drain 2 1 2 Dia Overflow C Drain Clearance Drain Center Overflow Center 1 1 4 1 1 4 60 8 1 2 22 3 4 5...

Page 3: ... illustrated S model apron extends down to room floor 2 Dia Drain 4 1 4 2 1 2 Dia Overflow 1 3 8 Drain Clearance Drain Center Overflow Center 6 Leveling Supports 1 1 4 Arm Rest Arm Rest Beveled Edge 15 1 8 20 3 4 51 1 2 60 9 42 43 1 4 21 21 22 16 1 2 2 Styllis BA 6042 Styllis BA IF 6042 illustrated BA model apron extends down to room floor Styllis BA 6036 Styllis BA IF 6036 illustrated BA model ap...

Page 4: ... Drain 4 1 2 1 3 4 Drain Clearance Leveling Supports 1 1 4 Beveled Edge 16 1 2 14 3 4 20 3 4 36 36 42 8 1 4 33 3 4 22 43 1 4 1 1 4 72 2 1 2 Dia Overflow 2 Illustration 1d Front Center Drain Unit Dimension Alcove Framing Guidelines dimensional tolerance 0 3 8 Model 01 02 03 04 05 06 07 08 BA 5429 54 30 1 4 29 14 1 2 8 10 1 2 12 10 1 2 BA R 41 60 30 1 2 29 1 4 14 1 4 8 1 2 11 11 3 4 13 1 2 BA R 51 6...

Page 5: ... the magnet alignment edges of the two outside re ceiver plates with your fingers Angle the panel top in toward the unit apron and attach the receiver plates to the outside magnets ensuring the alignment edge is above the top of the magnet illust 8 3 Once the top of the panel is aligned complete the attachment by pushing the bottom of the panel against the lower magnet assemblies until they catch ...

Page 6: ...xing will depend on unit usage and water quality WARNING NEVER APPLY WAX TO THE UNIT FLOOR u Routine Cleaning Mild non abrasive cleaner specifically formulated for gelcoat and acrylic surfaces recommended Rinse surface thoroughly u Heavy Soap Deposits Liquid ammonia household cleaner applied full strength Rinse surface thoroughly u Stubborn Stains Liquid household cleaner or hydrogen peroxide appl...

Page 7: ...UT IN Illustration 9 Panel Adjustment Panel Angled For Reattachment Adjustable Magnet Assembly Top Receiver Plate Magnet Alignment Edge Attach Top of Panel First Illustration 8 Panel Attachment Removable Panel Top Receiver Plate Adjustable Magnet Assemblies Bottom Receiver Plate Pull Panel Bottom Out To Remove Illustration 7 Panel Removal ...

Page 8: ...y service connections beyond the recommendations supplied by Oasis and within the scope of applicable codes and ordinances or b Carelessness damage abuse misuse negligence improper care fire flood or acts of God or c Non conforming use including any use beyond those intended for the product system option and or accessory including failure to follow the Prescribed Care and Maintenance Instructions ...

Reviews: