OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING DIAGRAM - PAGE 2 of 2
CAUTION! GFCI BREAKER USE REQUIREMENT
If N.E.C. (National Electric Code) or your local code
requires GFCI (Ground Fault Circuit Interrupter) protection,
you MUST use a GFCI breaker in lieu of a GFCI receptacle.
CAUTION! ADVERSE CONDITIONS / SPACING ISSUES
Performance issues caused by adverse conditions are NOT warranted.
End panels must be tightly joined or kept at least 6-inches away from
any structure to prevent condensation.
Unit must be kept at least 15-feet from exterior doors, overhead HVAC
vents or any air curtain disruption to maintain proper temperatures.
Unit must not be exposed to direct sunlight or any heat source
(ovens, fryers, etc.).
Keep at least 8-inch clearance above unit for air discharge
(self-contained units only).
CAUTION
CAUTION! LED LAMP REPLACEMENT GUIDELINES
LED lamps reflect specific size, shape and overall design.
Any replacements must meet factory specifications.
CAUTION
PRECAUTIONS
This sheet contains important precautions to prevent
damage to unit or merchandise.
Please read carefully!
See previous page for specifics on
OVERVIEW,
CONDITION TYPE, COMPLIANCE
and
WARNINGS
.
WIRING DIAGRAM
Each case has its own wiring diagram folded and in its
own packet.
Wiring diagram placement may vary; it may be
placed near ballast box, field wiring box, raceway
cover, or other related location.
REFRIGERANT DISCLOSURE STATEMENT
This equipment is prohibited from use in California
with any refrigerants on the “List of Prohibited
Substances” for that specific end-use, in accordance
with California Code of Regulations, title 17, section
95374.
This disclosure statement has been reviewed and
approved by Structural Concepts and Structural
Concepts attests, under penalty of perjury, that these
statements are true and accurate.
CAUTION! WATER ON FLOOR CAN CAUSE EXTENSIVE DAMAGE
Before powering up unit:
Check that drain lines flow directly to floor drain.
Units with optional Clean Sweep™ MUST be properly connected.