8
CEILING ORIGINATED ELECTRICAL & REFRIGERATION LINES / KNOCKOUT REMOVAL / SEALING
1. Merchandiser Versatility
Structural Concepts cases can accompany
either floor or ceiling-originated electrical and/or
refrigeration lines.
This page shows how ceiling-originated lines
are routed into case.
2. Ceiling Routed Electrical/Refrigeration. Lines
A center pass-through protective plate is mount-
ed at top of case over two (2) PVC center
pass-throughs.
If electrical/refrigeration lines are ceiling-
originated, remove plate knockouts.
Electrical and/or refrigeration lines may then be
dropped through PVC center pass-throughs.
Caution! If ceiling-originated lines are used,
you MUST seal both upper and lower PVC
Center Pass-Through
Protective Plate Shown After
Removal of Knock-Outs
center pass-throughs (at entrance points) with
expandable foam sealant to prevent
condensation in case.
3. Plate Removal
Note: Though not required, protective plate can be
removed from merchandiser via four (4) screws.
4. Case Underside
See
REFRIGERATION FUNDAMENTALS:
UNDERSIDE LAYOUT (BOTH
SELF-CONTAINED & REMOTE)
section in this
manual for location of center pass-throughs at
underside of case.
Center Pass-Through Protective
Plate Mounted on Merchandiser
Caution! If ceiling originated lines are
used, you MUST seal both upper and
lower PVC center pass-throughs (at
entrance points) with expandable
foam sealant to prevent
condensation in case.