background image

2

OASIS AQUA POINTE® ELECTRONIC BOTTLE FILLER INSTRUCTIONS

1. INSPECTION

 Inspect the cartons and various components for evidence of rough handling and concealed damage. 
Damage claims should be filed with the carrier. 

2. INSTALLATION, PLUMBING & ELECTRICAL CONNECTIONS

 

a)

 Note: The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC,  

SD, TX, VT and WI.  CA, KS, MN, NM and OR allow for a state-registered installer or contractor as well.  State 
and local plumbing codes may prohibit the use of saddle tapping valves for water line connection in some 
applications.  All connections must conform to applicable plumbing codes. 
 

b) 

Plumbing rough-in and wall opening should be prepared as shown on roughing-in drawing.  This 

drinking water cooler is designed to be operated at a water supply line pressure of up to 100 psi (690 kPa).  
A pressure regulator must be installed in front of the unit’s water inlet if the pressure (including any possible 
pressure spikes) could exceed 100 psi (690 kPa). 
 

c)

 Insert frame assembly into wall opening and secure to studs.  NOTE: FRONT FLANGE OF FRAME(S) 

MUST BE FLUSH WITH THE FINISHED WALL SURFACE. 
 

d) 

Install drain receptor to frame with screws provided. 

 

e)

 A 2X4 junction box is provided for the installation of a 115 volt receptacle.  The bottle filler is provided 

with a power cord with a grounded NEMA 15 plug.  This unit is intended to be connected to a ground fault 
circuit interrupting (GFCI) device to meet UL requirements.  It is recommended that flexible conduit be used to 
supply power to the junction box and chiller if used.  Check the electric current available.  Type and voltage 
must be the same as listed on the unit data plate. 
 

f)

 As the bottle filler panel assembly is being placed on the frame assembly, feed the long green 

ground wire and the terminals on the power supply cord through the bushings in the frame assembly. 
 

g) 

Attach the long green ground wire to the frame assembly junction box ground, then plug in bottle 

filler power cord. 
 

h)

 Refer to the appropriate connection diagram for water and drain connections.  Check for leaks. 

 

i) 

The lower panel can be secured with the provided key locks or screws.  The M8EBQ features one 

lockable and one non lockable lower panel; these are interchangeable. 

MODELS WITH CHILLER 

 

j)

 Attach cradle mounting angles to unit mounting cradle with 4 screws provided.  Slide unit mounting 

cradle into frame and secure in place with 4 screws, provided. (Cradle is used only when cooling unit is to be 
installed).   NOTE: BOTTOM FLANGE ON CRADLE IS TO BE BEHIND FRAME FRONT FLANGE. 

 

k) 

Slide cooling unit onto cradle. 

M8EBQ & M12EBQ WITH FOUNTAIN 

 

l)

 Install the fountain mounting plate to the frame assembly using the provided screws. 

 

m)

 Place the upper panel in place on the frame top angle and fasten with 2 screws, provided, at the 

bottom. 
 

n) 

Remove the bottom plate from the fountain arm.  Save the screws. 

 

o)

 Snap the reveal gasket over the back end of the fountain arm. 

 

p)

 Add compression connector, furnished by others, to the fountain waste tube and slide back 

approximately 3” out of the way.  Refer to the appropriate connection diagram. 
 

q)

 Hang the fountain on the mounting plate studs.  NOTE: AS THE FOUNTAIN IS HUNG, FEED THE WASTE 

TUBE INTO THE WASTE STUB ON THE WALL SIDE. 
 

r)

 Tighten the fountain to the mounting plate with the 5/16-18 nuts and washers and the 1/4-20 bolts 

and washers provided. 
 

s) 

Slide the reveal gasket(s) back into the notch between the panel and the arm.  The gasket serves as 

an appearance item only (to close up any opening around the panel and the mounting plate). 

Summary of Contents for MWEBQ

Page 1: ...Electronic Bottle Fillers MWEBQ MW8EBQ MW12EBQ MWSMEBQ MWSM8EBQ MWSM12EBQ M8EBQ M12EBQ MF2EBQ MW8F2EBQ MW12F2EBQ MWSMF2EBQ MWSM8F2EBQ MWSM12F2EBQ M8F2EBQ M12F2EBQ Please read these instructions befor...

Page 2: ...te f As the bottle filler panel assembly is being placed on the frame assembly feed the long green ground wire and the terminals on the power supply cord through the bushings in the frame assembly g A...

Page 3: ...catch water and remove drain plug 6 MAINTENANCE systems with chiller The only maintenance required is the removal of dirt and lint from the condenser Inspection should be made at 3 month intervals Re...

Page 4: ...the dispense stops During non use periods the QUASAR automatically cycles ON for ten seconds every ten minutes This keeps the dispense point more sanitary between use When the QUASAR is ON the LED li...

Page 5: ...No action needed YELLOW BOTTLES SAVED Standby mode filter life 80 used but 100 Order new filter RED BOTTLES SAVED Standby mode filter life 100 used Replace the filter BLUE UVC DISINFEC TION IN PROCES...

Page 6: ...TE DRAIN HEIGHT 4 5 16 110 21 7 32 539 FRAME 3 1 2 89 2 5 32 55 8 1 16 205 3 1 16 78 1 1 2 38 5 16 8 DIA MOUNTING HOLES 4 TOP AND 4 BOTTOM NOTES RECOMMENDED ADULT HEIGHT INTALLATION SHOWN ADJUST VERTI...

Page 7: ...1 16 78 8 1 16 205 1 1 2 38 ELECTRICAL CONNECTIONS 5 11 32 136 3 1 2 89 9 7 8 251 ELECTRICAL OUTLET OPTIMUM LOCATION SEE NOTE 4 11 1 2 292 44 11 16 1135 VERSAFILTER III APPROX LOCATION IF APPLICABLE I...

Page 8: ...ONS AS REQUIRED TO COMPLY WITH FEDERAL STATE AND LOCAL CODES STOP VALVE TRAP PIPE CONNECTOR TO WASTE LINE NOT PROVIDED SHORT RADIUS TRAP REQUIRED ALL DIMENSIONS ARE IN INCHES DIMENSIONS IN ARE IN MILL...

Page 9: ...g angles 2 provided Cooling Unit mounts inside cradle Lower Front Panel mounts to frame with bottom screws or optional locks 2 provided Trim Bezel accessory on surface mount models only MWSMEBQ MWSM8E...

Page 10: ...efore continuing with step 1B Place drip tray in frame but do NOT fasten in place Do NOT place grille on tray until last step Section 6 Install snap bushings Install provided ball valve and 3 8 O D co...

Page 11: ...tall Provided Stem Elbows Cut water line shown from solenoid valve out to bottle filler delivery fitting Squeeze end of tube back to round shape as needed Connect tube from solenoid valve out to filte...

Page 12: ...d to be connected to a ground fault circuit interrupting GFCI device to meet UL requirements It is recommended that a flexible conduit be used to supply power to the junction box and chiller if used C...

Page 13: ...frame per rough in drawing Screws Provided 4 Place chiller in frame Install 1 4 union fittings on chiller inlet and outlet Connect water line from bottle filler solenoid valve out to chiller water in...

Page 14: ...low Screw provided Install the 1 4 stem elbows provided in filter Inlet and outlet Place the filter in clip as shown Cut water line from buttle filler solenoid valve out to connect to filter in Squeez...

Page 15: ...to the chiller in the location shown on PAGE Install stem elbows provided on the in line filter and place in the in line filter in the previously installed clip Mount the VersaFilter III in the locat...

Page 16: ...ch remaining tubing from ball valve to chiller inlet Remove reducer fitting and copper tube from fountain water line Install provided 1 4 union Determine length of tube needed to connect bottle filler...

Page 17: ...me but do NOT fasten in place Do NOT place grille on tray at this time Install Snap Bushing and any other accessories included Uncoil EBQ push button wire lead and route through same opening in frame...

Page 18: ...or 3 seconds to reset Gallon or Liter count or momentarily press to advance to next menu FILT CAPAC OF 4750 GAL 18000 LTR Depress button for 3 seconds to change filter capacity to 1250 GAL 5000 LTR fo...

Page 19: ...19 SECTION 8 PARTS BREAKDOWN 1 2 8 3 4 6 5 7 28 9 10 15 16 18 24 20 21 17 22 11 12 13 19 23 14 25 26 27...

Page 20: ...05 1 12 LOCK ASSY 031657 006 2 13 POWER SUPPLY 12VDC 038036 003 1 14 PCB IR SENSOR 042065 001 1 15 LENS PWEBF LCD 042575 001 1 16 SPOUT 042368 001 1 17 LEAD WIRE ASSY 10FR BLACK 017340 512 1 18 LEAD W...

Page 21: ...21...

Page 22: ...Modular Series Electronic Bottle Fillers www oasiscoolers com 1 800 646 2747 2022 LVD Acquisition LLC OASIS QUASAR Aqua Pointe remedi Versafiller and Versafilter are registered trademarks of LVD Acqui...