1.
Temporarily position the compressor in the mounting location to ensure fit and
adequate clearance. Be sure location is sturdy enough to support compressor
properly.
2.
Drill four holes in the mounting surface to line up with the four holes in the
bottom of the compressor, and mount using four 3/8”-16 cap screws or studs on
the bottom of the compressor.
3.
Install an air filter or fitting for a filtered intake line into the suction port, and
an air hose or air line fitting into discharge port. Use heat resistant hose or
tubing.
Warning: Do not tighten fittings to more that 20 ft/lbs (finger tight
plus no more than one full turn). Doing so may crack the head! Do not
use Teflon tape! Pieces of tape can get sucked into the compressor valves.
We recommend the use of Loctite #567 high temp pipe thread sealant.
4.
Use a clutch with a properly tapered bore to drive the compressor. Ensure the
clutch is sized for proper RPM. For continuous duty applications do not
exceed 2000 rpm.
5.
Use a pressure switch to control the clutch and shut the compressor off at
200psi or less. Read item #9 under SAFETY INFORMATION!
6.
For installations involving tanks, some applications may require the use of a
one way check valve at the output of the compressor to prevent air flow back
into the compressor.
7.
Some oil vapor discharge during operation is normal. If an application
requires oil free air delivery, a coalescing air line filter may be required to
separate oil mist and moisture out of the air line. The filter must be rated at
least 175 deg. and should be located at the output of the tank.
8.
Compressor is shipped with oil. Check oil sight glass after compressor has
been sitting level for at least one hour. If oil level is not visible within a few
minutes, add oil until it is visible in window. Use a full synthetic, SAE 30 (ISO
100) weight air compressor oil.
Oil Sight Glass with proper oil level
If you are unsure about any part of installation or operation, contact the
manufacturer for clarification.
OPERATING NOTE
All air compressors generate heat. Excessive heat build up will destroy this product very
quickly, and
will void warranty
. Factors that affect temperature generation at the head
are operating RPM and pressure. The faster the pump is run, and/or the higher the
pressure it is operated at, the more heat will be generated. Ducted air flow aimed
directly at the head will help manage heat build up.
Do not allow head temperatures
to exceed 350 degrees F
. If in doubt about the suitability of this product for a particular
application, run a qualification test before placing the compressor in service.
MAINTENANCE
Check oil level after every 50 hours of operation. If no oil is visible in window, remove
oil plug from side of compressor and add oil until visible in window. Use a full
synthetic, SAE 30 (ISO 100) weight air compressor oil.
Ensure air intake filter is clean at all times.
LIMITED WARRANTY:
This product is warranted against defects in workmanship or materials for the period of one year
from the date of purchase by the original owner.
What is not covered under this Warranty:
1.
Merchantability and fitness for a particular purpose.
2.
Any indirect, incidental or consequential loss, damage or expense that may result
from any defect, failure or malfunction of this product.
3.
Failures that result from accident, abuse, neglect, lack of maintenance, attempts to
disassemble or repair, or failure to operate in accordance with instructions.
4.
Items or service required to maintain the product: i.e. lubricants and filters.
Warning: Warranty is void if unit is disassembled or operated without proper lubrication!
Oasis Mfg. will replace or repair at its option, products or components which have failed during
the warranty period due to defects in workmanship or materials.
Purchaser is responsible to deliver product to Oasis Mfg. at purchaser’s own expense, via
traceable carrier, package insured.
Oasis Manufacturing
23011 Alcalde #P
Laguna Hills, CA 92653
888-96-OASIS (Toll Free)
949-768-4311 Tel. 949-768-4677 Fax
www.oasismfg.com