Notice: If the device can not detect the engine speed, there is 
probably something wrong with the engine regulator or the 
connection breakdown with the battery. If the device can not detect 
the charging voltage, the device can skip the engine speed test, 
then the result will show  “No voltage input”. Please check the 
connection between engineer and battery and then test again.

 

 

Results for charging system test 
 

Charging voltage: normal 

The charging system shows that the output of the  generator is 
normal and no problems are detected. 
 

Charging voltage: low 

Insufficient charging voltage of charging system 
Please  check whether the generator belt is skidding or 
disconnecting, check whether the connection between the 
generator and the battery is normal. 
If the transmission belt and circuit is connected well, please 
troubleshoot the generator according to the manufacturer's 
suggestion. 

Summary of Contents for BT06

Page 1: ...e battery Put the red and black clamp to the battery to be tested Red clamp for positive black clamp for negative It will show start up interface on the screen The voltage of the battery to be tested...

Page 2: ...testing state It refers to if the battery is inside the vehicle with load connected If so choose Inside vehicle If not choose outside vehicle Step2 Choose charge state It refers to if the charge of t...

Page 3: ...standard It refers to the factory marked standard for the battery which is shown on the right above or the front battery Choose the marked standard such as CCA JIS and etc If there is no standard show...

Page 4: ...Step5 Choose rated capacity It refers to factory starting current standard which is shown on the right above or the front battery Such as 55B24...

Page 5: ...off lamp and door that can not start the vehicle and etc there will be a prompt please replace the battery For this kind of battery please consult with the battery manufacturer fist and replace and ch...

Page 6: ...e prompt and the device will finish the starting system test automatically and show the result Step3 Test result includes start time start voltage and voltage state In general start voltage lower than...

Page 7: ...he battery test results are displayed In this way the maintenance personnel can quickly determine the overall condition of the starting system according to this data Charging system test 1 After start...

Page 8: ...ging system test and operate according to the prompt and please seep up to 3000 RPM and keep for 5s 2 After test is finished the device will show charging voltage on load voltage and diode ripple as s...

Page 9: ...r and battery and then test again Results for charging system test Charging voltage normal The charging system shows that the output of the generator is normal and no problems are detected Charging vo...

Page 10: ...14 7v Charging too high will make the battery go through charging thus shortening the life of the battery and causing it to malfunction No voltage output The generator voltage output is not detected...