background image

Application Note:Installation tips for installing Oberon NEMA 4 Enclosures  

Copyright 2017 Oberon, Inc.  

9/21/2017 

 

Oberon Model 1021-00 enclosure with screw on cover

 

 
 
Cable Egress and NEMA 4

 

 
The Models 1020 and 1021 are easily drill for cable pass through and installing 
accessories. The most important step during installation is to ensure connectors 
are properly sealed to maintain the NEMA 4 rating. Water tight conduit such as 
Anamet Sealtite® coupled with a cable gland or other sealing connector may be 
used to prevent fluid from entering the enclosure. 
 
A  pressure  equalizing  vent  such  as  a  GORE®  Vent  may  be  help  reduce 
condensation. The GORE® Vent allows air pressure equalization between inside 
and outside the enclosure, yet restricts the passage of water vapor from outside 
to inside. This can help to reduce condensation.  
 

Model 3010 Installation on Uneven Surfaces 
 

Oberon’s  Model  3010  incorporates  a  sturdy  Aluminum  back  panel  that  fastens 
down to a surface. As with the Models 1020 and 1021, choose a surface that is 
smooth  and  level  for  installation.  Four  cushioning  washers  are  provided  with 
each  product  to  lift  the  back  panel  about  1/8"  above  the  potentially  uneven  or 
irregular surface. Fastening the back panel without the cushioning washers on an 
uneven  surface  may  cause  bending  and  flexing.  If  the  panel  is  bent,  the  cover 
holes will no longer align properly to the panel hardware, and the gasket will not 
seal flat along the plane surface. When fastening to a surface, use wall anchors 
suited for the wall material or construction, and tighten to the same torque on all 
sides. 

Reviews: