Choose an appropriate location for data and power ingress. Drill an appro-
priately sized hole into the enclosure to fit the selected conduit size. Fasten 
the conduit to the drilled hole. 

 

(For installations using wall mount brackets ONLY)

 Fasten the wall 

mount brackets to the back of the enclosure using the provided M4 x 8 mm 
flat head screws.

 

Elija una ubicación adecuada para el ingreso de datos y energía. Taladre un 
orificio del tamaño apropiado en el gabinete para que se ajuste al tamaño 
del conducto seleccionado. Fije el conducto al orificio perforado.

 

(SOLO para instalaciones que utilizan soportes de montaje en pared)

 

Sujete los soportes de montaje en pared a la parte posterior del gabinete 
utilizando los tornillos de cabeza plana M4 x 8 mm provistos.

 

1

 

(For 

-

ANTPLATE SKUs Only)

 Install the antenna mounting bracket and 

access point mounting bracket, or included T

-

Bar Bracket, to the internal 

panel with the provided #6 x 3/8” screws.

 

(Solo para SKU 

-

ANTPLATE)

 Instale el soporte de montaje de la antena 

y el soporte de montaje del punto de acceso, o el soporte incluido de la 
barra en T, en el panel interno con los tornillos #6 x 3/8” provistos.

 

2d

 

3a

 

To mount the Cisco AIR

-

BRACKET

-

1 or 

-

2, align the bracket’s four (4) 

“A” marked holes with the four (4) embosses on the enclosure base la-
beled “A” on the mounting legend.

 

If installing the AIR

-

BRACKET

-

1, use the four (4) provided #6 x 5/16” flat 

head screws to fasten the bracket to the enclosure base. 

 

If installing the AIR

-

BRACKET

-

2, use the four (4) provided #6 x 5/16” 

pan head screws to fasten the bracket to the enclosure base. 

 

Para montar Cisco AIR

-

BRACKET

-

1 o 

-

2, alinee los cuatro (4) agujeros 

marcados con "A" del soporte con los cuatro (4) relieves en la base del 
gabinete etiquetados como "A" en la leyenda de montaje.

 

Si instala el AIR

-

BRACKET

-

1, use los cuatro (4) tornillos #6 x 5/16” de 

cabeza plana provistos para fijar el soporte a la base del gabinete.

 

Si instala el AIR

-

BRACKET

-

2, use los cuatro (4) tornillos #6 x 5/16” de 

cabeza plana provistos para fijar el soporte a la base del gabinete.

 

To mount the T

-

Bar bracket, align the bracket’s holes with the two (2) 

embosses labeled “B” on the mounting legend. Fasten the T

-

Bar Bracket 

directly to the enclosure using two (2) of the provided #6 x 5/16" pan 
head screws.

 

Para montar el soporte de la barra en T, alinee los agujeros del soporte 
con los dos (2) relieves etiquetados "B" en la leyenda de montaje. Sujete 
el soporte de la barra en T directamente al gabinete utilizando dos (2) de 
los tornillos de cabeza plana #6 x 5/16" provistos.

 

Use (4) #10 x 2” screws (not included) and suitable anchor hardware (not 
included) to fasten to the wall or surface. 

 

(For installations that require cushioning washers)

 Insert a cushioning 

washer between each of the wall mount brackets and the wall or surface. 

 

Tighten the screws uniformly around the box so that it does not flex.

 

Use (4) tornillos #10 x 2” (no incluidos) y herrajes de anclaje adecuados (no 
incluidos) para fijar a la pared o superficie.

 

(Para instalaciones que requieren arandelas de amortiguación)

 Inserte 

una arandela de amortiguación entre cada uno de los soportes de montaje 
en pared y la pared o superficie.

 

Apriete los tornillos de manera uniforme alrededor de la caja para que no se 
doble.

 

2a

 

Cisco

 

2b

 

Aruba

 

Other

 

2c

 

Other

 

The universal mounting bracket is required to mount other types of APs.  
It can also be used as an alternate method of mounting the T

-

Bar (shown 

above) or the Cisco Air

-

Bracket. 

 

(For 

-

ANTPLATE SKUs Only)

 The Universal Mounting Bracket is re-

quired to mount both the antenna mounting bracket and the AP mounting 
hardware.

 

To install the universal mounting bracket, fasten it to the enclosure using 
the four (4) provided M4 x 8 mm Pan Head Screws. Use the provided #6 
x 5/16” screws to mount the T

-

Bar, the Cisco Air

-

Bracket, or to directly 

mount other APs to the mounting bracket.

 

Se requiere el soporte de montaje universal para montar otros tipos de 
AP. También se puede usar como un æmétodo alternativo para montar la 
barra en T (que se muestra arriba) o el soporte de aire de Cisco.

 

(Solo para SKU 

-

ANTPLATE)

 Se requiere el soporte de montaje univer-

sal para montar tanto el soporte de antena como el hardware de montaje 
AP.

 

Para instalar el soporte de montaje universal, fíjelo al gabinete utilizando 
los cuatro (4) tornillos de cabeza plana M4 x 8 mm provistos. Use los 
tornillos #6 x 5/16" provistos para montar la barra en T, el soporte de aire 
de Cisco o para montar directamente otros AP en el soporte de montaje.

 

Aruba

 

Other

 

Cisco

 

***NOTE: The AP maximum operating temperature should be 
de

-

rated by 11°C inside the enclosure when solar loading is 

not present. The Model 1021 is white to reduce solar loading, 
while painting the enclosure a darker color will increase solar 
loading. Avoid mounting the 1021 where it is exposed to direct 
sunlight.

 

***NOTA: La temperatura máxima de funcionamiento AP debe 
reducirse en 11°C dentro del gabinete cuando no hay carga 
solar. El modelo 1021 es blanco para reducir la carga solar, 
mientras que pintar el gabinete con un color más oscuro au-
mentará la carga solar. Evite montar el 1021 donde esté ex-
puesto a la luz solar directa.

 

***NOTE: For steps 2a, 2b, 2c, and 2d, reference the mounting 
legend on page 1.

 

***NOTA: Para los pasos 2a, 2b, 2c, y 2d, consulte la leyenda 
de montaje en la página 1.

 

***NOTE: If the wall or surface to which the enclosure is at-
tached is not completely smooth and flat, it is recommended 
that the cushioning washers be placed between the mounting 
tabs and the wall or surface. The cushioning washers will 
reduce flexing by the enclosure when tightened against an 
uneven surface, which can cause the seal between the lid 
and box to open.

 

***NOTA: Si la pared o superficie a la que se adjunta el gabi-
nete no es completamente lisa y plana, se recomienda colo-
car las arandelas de amortiguación entre las pestañas de 
montaje y la pared o superficie. Las arandelas de amorti-
guación reducirán la flexión del gabinete cuando se aprietan 
contra una superficie irregular, lo que puede hacer que se 