The locking Model
1047 series enclosure provides a convenient way to
mount and secure most APs in a suspended ceiling. The AP is mounted
in the door. Interchangeable retrofit doors permit vendor and technology
migrations, and simplify moves, adds, and changes. UL listed for installa-
tion in the plenum space.
El gabinete de bloqueo de la serie Modelo 1047 proporciona una manera
conveniente de montar y asegurar la mayoría de los AP en un techo
suspendido. El AP está montado en la puerta. Las puertas de actualiza-
ción intercambiables permiten migraciones de proveedores y tecnología,
y simplifican movimientos, adiciones y cambios. Listado por UL para
instalación en el espacio plenum.
Instructions are for typical install conditions.
Instructions may not be correct for all installations due to building
design, construction materials or methods used and/or building or
site conditions. Consult a contractor or architect for recommenda-
tions. For product questions call (+1) 877
-
867
-
2312.
Las instrucciones son para condiciones típicas de instalación.
Las instrucciones pueden no ser correctas para todas las instala-
ciones según el diseño del edificio, materiales de construcción o
métodos utilizados, o condiciones del edificio o del lugar. Consulte
a un contratista o arquitecto para obtener recomendaciones. Si
tiene preguntas con respecto al producto, llame al (+1) 877
-
867
-
2312.
Thank you for choosing Oberon./ Gracias por elegir Oberon.
WARNING
/ ADVERTENCIA
Follow manufacturer's instructions for hand or power tools.
Always use safety glasses. Failure to do so may result in injury
and/or product damage.
Siga las instrucciones del fabricante para herramientas manu-
ales o eléctricas. Utilice siempre gafas de seguridad. Si no lo
hace, podría producirse lesiones y / o daños al producto.
WARNING
/ ADVERTENCIA
Use caution when working at elevated heights. Follow manu-
facturer's instructions for ladders and/or scaffolding. Failure to
do so may result in injury or death.
Tenga cuidado al trabajar a alturas elevadas y alrededor de las
aberturas de la unidad. Siga las instrucciones del fabricante
para laddors y / o andamios. Si no lo hace, podría causar le-
siones o la muerte.
Important Information for Model 1047
/ Información importante sobre la instalación del modelo 1047
Read guide from beginning to end before beginning installation.
Read all warnings and cautions before beginning unit installa-
tion. Check with your local building code official to identify and
confirm compliance with local building code requirements. This
installation guide covers installing your Model 1047 in a typical
environment. The appropriate method for your installation may
vary based on building design, application, and industry practic-
es.
Lea la guía de principio a fin antes de comenzar la instalación.
Lea todas las advertencias y precauciones antes de comenzar la
instalación de la unidad. Verifique con un oficial de código
edilicio de su localidad para identificar y confirmar el cumpli-
miento con los requisitos locales del código de edificación. Esta
guía de instalación cubre la instalación del Modelo 1047 en un
entorno adecuado. El método apropiado para la instalación
puede variar según el diseño del edificio, la aplicación y las
prácticas de la industria.
1. Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical Continuity of Metal Raceways and
Enclosures) and 300.11 (Securing and Supporting). Independent support wires or other means must be used for the installation of this product in the ceiling.
Acoustical, suspended, false, drop and concealed spline ceiling grid work is not designed to support the weight of this product. Oberon’s ceiling mounted
products have four support wire tabs on the back box. These tabs shall be used for supporting the product with independent support wires, wire rope, thread-
ed rod, or other secure support means of adequate gauge and fire resistance.
2. The Cabinet System Communication is configured in the field by qualified service personnel.
3. When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door from accidentally swinging open.
4. When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open.
5. This enclosure has a maximum operating ambient of 55º C (131º F). The temperature within the enclosure may not exceed this temperature, depending on
power dissipation within enclosure.
6. A minimum air clearance of 1“ between the housing of the access point and the enclosure side walls must be maintained for the safe operation of the
equipment.
7. This product is intended to be installed by trained personnel.
8. Only Listed ITE products shall be installed within the enclosure.
9. This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or replacement.
10. Maximum weight to be installed in the unit is 25 lbs.
11. All knockouts, openings, and holes shall be sealed with a plug constructed of metal, or a non
-
metal material that complies with UL 2043 or UL 1479.
12. All unused mounting holes should be sealed with tape or other material that complies with UL 1479.
13. AC Power is not to be used inside the enclosure.
14. A readily accessible disconnect device shall be incorporated in the building installation wiring.
15. See OSHPD approved installation drawing where applicable.
1. Los productos a montar en el cielorraso deben instalarse de acuerdo con los párrafos 300.10 (Continuidad Eléctrica de Canalizaciones y Recintos de Met-
al) y 300.11 (Aseguramiento y Soportes) del Código Eléctrico Nacional. Deben utilizarse cables independientes de soporte u otros medios para la instalación
de este producto en el cielorraso. Las rejillas de cielorraso estriadas acústicas, suspendidas, falsas, en desnivel y ocultas no están diseñadas para soportar
el peso de este producto. Los productos para montar en cielorraso de Oberon tienen cuatro pestañas para cable de soporte en la caja posterior. Estas pesta-
ñas deben utilizarse para sujetar el producto con cables independientes, cables de acero, varillas roscadas u otro medio de soporte seguro, de caliber adec-
uado y resistencia al fuego.
2. La comunicación del sistema del gabinete está configurada en el campo por personal de servicio calificado.
3. Al cerrar la puerta de acceso al recinto, asegúrese de que el seguro de leva esté completamente trabado para evitar que la puerta de acceso se abra por
accidente.
4. Al abrir la puerta de la cubierta, asegúrese de sostener la puerta para evitar que se abra por accidente.
5. Esta cubierta tiene un entorno máximo de funcionamiento de 55 °C (131 °F). La temperatura dentro de la cubierta no puede exceeder este valor, de-
pendiendo de la disipación de energía dentro de la misma.
6. Debe mantenerse un espacio mínimo de 1" entre la carcasa del punto de acceso y las paredes laterales de la cubierta para el funcionamiento seguro del
equipo.
7. Este producto debe ser instalado por personal capacitado.
8. Solo productos homologados por ITE pueden instalarse dentro de la cubierta.
9. Este producto debe ser reparado por personal capacitado por el fabricante o devuelto al fabricante para su reparación o reemplazo.
10. El peso máximo a instalar en la unidad es de 25 libras.
11. Todos los perforados, las aberturas y los orificios deben sellarse con un tapón de metal o de un material no metálico que cumpla con las normas UL 2043
o UL 1479.
12. Todos los orificios de montaje sin usar deben sellarse con cinta u otro material que cumpla con la norma UL 1479.
13. Dentro de la cubierta no debe utilizarse corriente alterna.
14. Se deberá incorporar un dispositivo de desconexión fácilmente accesible en el cableado de la instalación del edificio.
15. Consulte el plano de instalación aprobado por OSHPD donde corresponda.
(1) Enclosure and Interchangeable Door /
Recinto y puerta intercambiable
(1) Dual Cable Egress Firestop Grommet /
Arandela cortafuegos doble salida de cable
(1) 1” Trade Size Conduit Connector /
Conector de conducto de tamaño comercial de 1"
(4) Hanger Wires /
Cables de suspensión
(2) Keys for Lock /
Claves para cerradura
(1) Universal Swing Down Mounting Bracket /
Soporte de montaje abatible universal hacia abajo
(2) #8
-
32 x 1/4” screws /
Tornillos #8
-
32 x 1/4"
(4) #6
-
32 x 3/8” screws /
Tornillos #6
-
32 x 3/8"
Access Point Attachment Hardware /
Hardware de fijación de punto de acceso
Important code and installation information.
/ Información im-
portante sobre normas e instalación.
Parts Included /
partes incluidas