Step  6  –  Run  the  data  and  power  cable  (if  required)  through  the  conduit  connectors  located  on  sides  of  the 

access  point 

enclosure

.  In order to maintain a separation of signal and power, install the data and power cables through opposite sides of 

the enclosure utilizing the two knock-outs provided. Insert foam into the conduit connector and pull the data cable through far 
enough  to  allow  attachment  to  the  access  point  (8"  -  10").  Carefully  tighten  conduit  connector  around  fire  block  foam  just 
enough  to  fill  in  gaps  around  cable.  Be  careful  not  to  over  tighten  and  crush  the  data  cable(s),  as  this  can  affect  cable 
performance. 
 
 
Step  7  –  Attach  data  and  power  cables  to  the 

access  point

  through  the  access  door  then  tighten  the  screws  on  the  cable 

clamp.  
 
Step 8 – Close and lock the access door. The installation is now completed. 

 
 
 
 

 
 
 
 
The Oberon Model 1052-AN-ANT16 access point enclosure is specifically designed to be used with the Aruba AP-120, 
and AP-124 access points.  

 

 
 
Page 4 

 

MODEL 1052-AN-ANT16 

Installation Instructions 

 

**** WARNING **** 

 

Please thoroughly read the product warning below 

before installation to provide for a safe work 

environment. 

 

1.  Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical 

Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or 
other  means  must  be  used  for  the  installation  of  this  product  in  the  ceiling.  Acoustical,  suspended,  false,  drop  and 
concealed  spline  ceiling  grid  work  is  not  designed  to  support  the  weight  of  this  product.  Oberon’s  ceiling  mounted 
products  have  four  support  wire  tabs  on  the  back  box.  These  tabs  shall  be  used  for  supporting  the  product  with 
independent  support  wires,  wire  rope,  threaded  rod,  or  other  secure  support  means  of  adequate  gauge  and  fire 
resistance. 

 

2.  When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door 

from accidentally swinging open. 

 

3.  When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open. 
 
4.  This  enclosure  has  a  maximum  operating  ambient  of  55º  C  (131º  F),  the  temperature  within  the  enclosure  may  not 

exceed this temperature, depending on power dissipation within enclosure. 

 
5.  A  minimum  air  clearance  of  1“  between  the  housing  of  the  access  point  and  the  enclosure  side  walls  must  be 

maintained for the safe operation of the equipment. 

 
6.  This product is intended to be installed by trained personnel. 
 
7.  Only Listed ITE and Listed AC Receptacles shall be installed within the enclosure. 
 
8.  This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or 

replacement. 

 
9.  Maximum weight to be installed in the unit is 25 lbs. 
 
10.  All  knockouts,  openings,  and  holes  shall  be  sealed  with  a  plug  constructed  of  metal,  or  a  non-metal  material  that 

complies with UL 2043 or UL 1479. 

 
11.  All unused mounting holes should be sealed with tape or other material that complies with UL 1479. 
 
12.  If  AC  power  is  used  inside  the  enclosure,  connect  the  ground  wire  to  the  green  ground  screw  located  near  the 

knockout in the backbox. 

 