background image

OBID

 

i-scan

 ® 

UHF 

Installation 

ID ISC.ANT.U270/270-FCC 

 

FEIG ELECTRONIC GmbH 

Page 5 of 16 

M30117-1e-ID-B 

 

1. Safety Instructions / Warning - Read before start-up ! 

  The device may only be used for the intended purpose designed by for the manufacturer. 

  The operation manual should be conveniently kept available at all times for each user. 

  Unauthorized changes and the use of spare parts and additional devices which have not been 

sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such 
unauthorized measures shall  exclude any liability by the manufacturer. 

  The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid 

for the device. The manufacturer shall  not be held legally responsible for inaccuracies, errors, 
or omissions in the manual or automatically set parameters for a device or  for an incorrect 
application of a device. 

  Repairs may only be executed by the manufacturer. 

  Installation, operation, and maintenance procedures should only be carried out by qualified 

personnel. 

  Use of the device and its installation must be in accordance with national legal requirements 

and local electrical codes . 

  When working on devices the valid safety regulations must be observed. 

  Special advice for carriers of cardiac pacemakers: 

Although this device doesn't exceed the valid limits for electromagnetic fields you should keep 
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in 
an immediate proximity of the device respective the antenna for some time. 

Summary of Contents for ID ISC.ANT.U270-FCC

Page 1: ...INSTALLATION final public B 2014 11 24 M30117 1e ID B ID ISC ANT U270 270 FCC Standard UHF Antenna...

Page 2: ...of this document FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for us...

Page 3: ...rmer issue If bits within one byte are filled with these bit spaces are reserved for future extensions or for internal testing and manufacturing functions These bit spaces must not be changed as this...

Page 4: ...Safety Instructions Warning Read before start up 5 2 Performance Features of the Antenna ANT U270 270 FCC 6 3 Installation 7 3 1 Mounting Holes 7 3 2 Installation with Mounting Set 8 3 3 Draining Hole...

Page 5: ...e valid for the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect applic...

Page 6: ...operating frequencies in the UHF range from 902 MHz 928MHz Due to the circular polarization a reading of Transponder in two orientations is possible The antenna is optimized for RFID applications unde...

Page 7: ...al structures or poles and can be ordered from FEIG ELECTRONIC GmbH NOTE When fastening the screws it must be ensured that the housing of the antenna is not bend Optionally the attachment points shoul...

Page 8: ...cial mounting set provides an easy method of mounting of the antenna at a portal mast pole or bar After mounting the antenna can be changed and positioned at three orientations Figure 2 Mounting Set w...

Page 9: ...These holes are used to guide condensing water out of the outer circle of the housing NOTE The protection class of the antenna is not affected by the draining holes The blocking that guarantees the pr...

Page 10: ...h a thin membrane that is used for pressure balance between the air inside the housing and the air outside the housing The mem brane is water resistant and does not influence the protection class of t...

Page 11: ...the antenna cable These cable assembly can be ordered by FEIG ELECTRONIC GmbH in a two meter 2 m or six meter 6 m version Table 3 Ordering Information Antenna Cable Length Description Order number 2...

Page 12: ...OBID i scan UHF Installation ID ISC ANT U270 270 FCC FEIG ELECTRONIC GmbH Page 12 of 16 M30117 1e ID B 4 VSWR Figure 5 Typical VSWR of the antenna ID ISC ANT U270 270 FCC...

Page 13: ...OBID i scan UHF Installation ID ISC ANT U270 270 FCC FEIG ELECTRONIC GmbH Page 13 of 16 M30117 1e ID B 5 Antenna Pattern The 3 dB Beamwidth of the antenna is 65 x 65 Figure 6 3 dB Beamwidth 65 65...

Page 14: ...55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 185 190 195 200 205 210 215 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 300 305 310 3...

Page 15: ...S Dimension W x H x D 273 mm x 273 mm x 58 mm Weight approx 1210 g Protection Class IP 65 Color White ELECTRICAL DATA Operating Frequency 902 MHz to 928 MHz Gain typ 9 0 dBic 3 dB Beamwidth E Plane H...

Page 16: ...FCC FEIG ELECTRONIC GmbH Page 16 of 16 M30117 1e ID B MECHANICAL DATA MOUNTING SET Material Aluminum steel zinc plate Clamping zone for circular profiles 30 mm to 60 mm Weight approx 400 g Alignment...