DOC-24000 Rev. C
7–43
Objet30 User Guide
•
If
the
replacement
head
was
not
factory
‐
calibrated,
the
following
warning
screen
appears.
Figure 7-58: Invalid-data warning screen
If
this
happens:
a. Remove
the
head
and
replace
it
with
another
one.
b. In
the
wizard
screen,
select
the
check
box
to
confirm
that
you
have
installed
another
head,
and
click
Next
.
c. Contact
your
authorized
Objet
Customer
Support
center
about
the
unformatted
head.
•
If
the
vacuum
test
is
not
successful,
the
replacement
head
was
not
sealed
properly
during
installation,
and
the
following
warning
screen
appears.
Figure 7-59: Vacuum Leakage warning screen
If
this
happens:
a. Click
Next
.
b. Follow
the
instructions
on
the
wizard
screens
to
re
‐
install
the
head.