Fuel
only use recommended fuel. Dry wood (less than 20% moisture content) or at least 2 years old cut.
avoid soft wood, painted or treated timber.
The ash pit drawer must always remain in the appliance during de-ashing. To open or close the door,
use a heat resistant glove.
Verification before operating the first times
During the first operations of the appliance a smell of paint evaporates from the appliance.
Ventilate the room to limit nuisance.
air control
use the heat resistant glove provided with the appliance to handle the instruments of control,
which could be very hot.
Burning rates
located on the front of the ash pit, this damper is used to regulate the rate of this appliance between
“ignition”, “normal rate” and “slow combustion”.
Warning:
putting the damper on “ignition” position allows an addition of air intake. This position is
to be used only for ignition and must be maintained no more than 30 minutes to avoid overheating damage.