background image

   page 9

oblica

 | argos model specifications

as/nZs standards

The argos has been Tested and approved under as/nZs standards as per below:

laBoratory:

  

Vipac engineers & scientist 

 

279 normanby rd, port Melbourne Vic 3207 

 

(03) 9647 9700

 

Vipac is a naTa accredited laboratory. 

 

registration number: 676.

title:

 

oblica – argos wood heater

WorK reQuested:

 

assessment of appliance to as/nZs 4012:1999 for 

 

determination of power output and efficiency and as/nZs 

 

4013:1999 for flue gas emission using hardwood fuel.

 

assessment of appliance in one configuration to as/nZs 

 

2918:2001 appendix B, with a full-length standard flue kit.

test date:

 

16/02/2012 to 08/03/2012.

test report numBer:

 

30a-12-0012-Trp-257791-0 

 

30a-12-0012-Trp-257790-0

inVestigating officers:

 

rhys connick, rebecca searcy.

certification

Summary of Contents for ARGOS

Page 1: ...argos model specifications Technical Data 2 Installation 3 Operate the Argos 5 Safety Rules 8 Certification 9...

Page 2: ...lly Australian Standards Test Results Manufacturer Data Power output 11kW 12kW Efficiency 56 76 Weight 169 Kg Dimensions h1250mm 532mm Flue sections Double skin 175 225mm Roof ceiling penetration Trip...

Page 3: ...uch heat shields has to be made in accordance with the BCA Building Code of Australia If the nearby surfaces are made of incombustible materials and do not get damaged under heat those clearances may...

Page 4: ...elow Place bottom of the deflector on the rear stops indicator no 2 on sketch Let the front of the deflector sit on the front stops indicator no 3 on sketch Step 1 Step 2 Step 3 Deflector assembly To...

Page 5: ...ates from the appliance Ventilate the room to limit nuisance Air Control Use the heat resistant glove provided with the appliance to handle the instruments of control which could be very hot Burning r...

Page 6: ...Place some crushed paper on the grid avoid glazed paper and some kindlings Lit the paper close the door of the appliance and fully open the air outlet Once the fire is well lit up you can load your ap...

Page 7: ...trains of intermittence cannot be respected or a reduced power is chosen In this case full power can be achieved over duration of 3 hours and at a reduced rate at low power 10 hours of operation are a...

Page 8: ...y During operation all the stove s surfaces are hot Be careful of burns Never try to modify the stove The use of fuels that are not recommended or unsuitable for the stove are forbidden including liqu...

Page 9: ...TITLE Oblica Argos wood heater WORK REQUESTED Assessment of appliance to AS NZS 4012 1999 for determination of Power Output and Efficiency and AS NZS 4013 1999 for Flue Gas Emission using hardwood fu...

Reviews: