info@obloliving.com

Congratulations and thank you for purchasing OBLO Li-

ving High Load Switch device. Below you will find useful 

operating guidelines.

DEVICE DESCRIPTION

OBLO Living High Load Switch SO10M1-ZB-B (Illustration 

1) is a device that allows you to control your home electri-

cal appliances or light switches remotely from anywhere. It 

also measures power consumption of the device attached 

to it and has automatic overload protection.The device is 

compliant with ZigBee Home Automation (ZHA) 1.2 and is 

guaranteed to function with any ZHA 1.2-compliant system. 

In addition, it allows pairing with any device supporting ZHA 

binding feature.

main button

connectors

secondary button

LED indication

Illustration 1

The device is equipped with overload protection circuit 

that automatically switches off the power if power con-

sumption exceeds factory defined limit of 2200W.

NOTE: 

When pressing secondary button, please use appropriate 

non-metallic tool.

WIRING

OBLO Living High Load Switch is easy to install into 

existing installations by replacing old sockets or light swi-

tches. 

 

Illustration 2: Connectors

Illustrations 3 and 4 are presenting two possible wiring 

methods. 

NOTE: 

Connectors N i N’ are short-circuited.

Illustration 3: Wiring method for controlling the socket

 

Illustration 4: Wiring method for controlling the light switch

OBLO Living High Load Switch is installed between the ma-

ins supply and the wall socket or light switch. High Load 

Switch breaks only one conductor - phase conductor, and 

must be installed in accordance with Illustration 3 in case 

when High Load Switch is controlling the socket, or in ac-

cordance with Illustration 4 in case when High Load Switch 

is controlling light switch. 

High Load Switch is equipped with overload protection cir-

cuit with factory defined limit of 2200W. In case that the 

device is connected to higher load for more than 2 seconds 

it will automatically turn off. In this case, LED indication will 

warn user of the overload (LED will blink red). When over-

load occurs, High Load Switch can be returned to normal 

mode by pressing the main button.

INSTALLATION

In order to install OBLO Living High Load Switch, please 

follow the procedure explained below. Installation elements 

are shown in Illustration 6. 

NOTE:

  In case you are not sure that you have enough 

knowledge about electrical wiring, please contact qualified 

technician to install the device.

1.  Turn off power at the electrical circuit at which you will 

install High Load Switch. Do this by switching off the 

appropriate fuse or MCB in the fuse panel or distribu-

tion board. Check the wires with a voltage detector to 

verify that the power is off.

2.  Prepare the wires in wall installation box by removing 

the insulation. Wire insulation should be stripped back 

5mm from the wire end (Illustration 5).

Illustration 5

3. Mount the OBLO Living High Load Switch into the wall 

box by following these steps:

1)  Place the switch button on the High Load Switch. 

Pay attention to the orientation of the device - 

check if pressure on the switch button causes a 

distinctive “click”.

2)  High Load Switch with switch button should be in-

serted into the center hole of the mounting frame. 

Push it from the front until you can hear a click. In 

case you are installing high load switch with outlet, 

do the same for the outlet. 

3)  Connect the wall box wires to the connectors on 

High Load Switch and outlet (in case you are in-

stalling High Load Switch with outlet) with a screw-

driver according to wiring method explained in Il-

lustration 3. Softly pull conductors to check if they 

are well fixed

4)  Carefully put the mounting frame into the box (so 

that the High Load Switch is inside the box) and 

secure it with screws.

5)  Put the decorative mask (1M or 3M mask with 

outlet) on the mounting frame and press it until 

you hear a click.

Decorative mask

Switch button 

Mounting frame

 High Load Switch

 Illustration 6: Installation elements

4. Turn on power at the electrical circuit of High Load Swi-

tch (return fuse or MCB to the original position).

5. Test the device to see if it is working properly. When 

turned on for the first time, LED indication should light 

red. If that is not the case, High Load Switch is either 

defective or has been already added to some ZigBee 

network. To restore your High Load Switch to default 

factory settings, see section Factory reset.

6. If High Load Switch is working properly, you need to 

configure it to operate as a standalone unit or as a part 

of OBLO Living home automation system.

PREPARATION

After powering up for the first time High Load Switch is not 

associated with any ZigBee network. In order to enable wi-

reless control feature, High Load Switch should operate as 

a standalone unit or as a part of OBLO Living home auto-

mation (HA) system.

HIGH LOAD SWITCH AS A STANDALONE UNIT

Please follow the procedure below to enable High Load 

Switch to function as a standalone unit:

1.  Create a new standalone ZigBee network:

1)  Press and hold secondary button (approx. 5 sec-

onds). After releasing the button, LED indicator 

starts blinking red and green alternately.

2)  Few seconds later, LED indicator will turn off, which 

means that new ZigBee network is created and 

opened for other devices to join it.