45 | EN
Screw-on cable tray systems
Mounting
5 5 6
Mounting the T branch piece
T branch pieces are mounted to create T branches with large bend radii.
Depending on their width, T branch pieces are available with or without
WKV angle connectors.
With connector, 100–300 mm cable tray width
1. Mount the WKV angle connector on the T branch piece.
Fig 51:
T branch piece with WKV angle connectors
Fig 52:
Pushing the cable trays onto the T branch piece
2. Push the cable trays onto the T branch piece. In so doing, the outer
cable tray rails are within the fitting. The straps of the WKV angle
connector are on the inner side of the cable tray rails.