OMC-042 / 043 / 044 Data loggers
Users
’ manual
page 16
You’ll see this screen:
First Rename your Device by
Selecting option 1
(General Settings)
After selecting “General
Settings” the screen will look like this:
< General settings>
1. Press 1 and enter the name of your preference
2. Choose your data logging interval. We used 10 minutes, and NO Alarming.
3. Enter the deployment date & time. This can be a time in the future when the logger should start
working. We will use the actual date & time to start right away.
4. Exit and save changes.
5. Now, the overall configuration is setup and we proceed with the configuration of the sensors and data
output.
General settings
[0] Exit
[1] System name >> Observator
[2] Data log interval >> 00:10:00
[3] Continuous alarm sampling >> Off
[4] Direct data output on data alarm >> Off
[-] Digital alarm output port >> Enabled
[6] Deployment date and time >> 2015/08/31 06:55:23
[7] Daily operating time slot >> 24 hour
[8] Time zone >> 0
[9] Summer time (daylight saving) >> Not used
>
Configuration setup
[0] Exit
[1] General settings >> Observator
[2] Modem settings
[3] NTP time update >> Not used
[4] Alarm SMS >> Not used
[5] SMS commands >> Not used
[6] Internal sensors >> Internal
[7] Analog sensors >> Not used
[8] Digital sensors >> Not used
[9] Network signal sensor >> Not used
[A] Serial port >> Not used
[B] Accessory port >> Not used
[C] Calculated channels >> Used
[D] DTU connection >> Not used
[E] Email output >> Not used
[F] FTP output >> Not used
[G] TCP output >> Not used
[H] HTTP output >> Not used
>