Display
This driver is intended for the operation of an Observator Instruments display unit. With this display unit,
the measurements can be consulted, locally, in a graphical way. The Observator Instruments display unit
is a 3.5” color resistive touch screen display with a resolution of 320*240 pixels.
The settings of the display are very simple and shown below:
Display settings
Power down delay
This is the time, the data logger shuts the display down, after not touched anymore. With this accessory
you can recall graphs, or numeric, actual values of all parameters. It has an auto-scale feature for
graphing and allows the user to browse the history of the measurements (via the graphs).
[0] Exit
[1] Name >> Display
[-] Port settings >> RS232 8N1; 115200 Baud
[3] Power down delay >> 00:01:00
[R] Remove
>