OMC-042 / 043 / 044 Data loggers
Users
’ manual
page 34
Average Voltage
The voltage of the connected battery, averaged to get a real practical value
Max Voltage
Battery Voltage, maximum of interval
Min Voltage
Battery voltage, minimum value of interval. This parameter is very practical to use for diagnostic
measurements. Particularly when the modem sends data, the battery voltage will drop, and must not get
too low (2 Volts) This parameter is a nice quality figure for the status of the battery. When this value drops
a lot, it is wise to exchange the battery, or charge it. With solar systems, in the dark months, this can be
an issue and this can be solved with the aid of good weather.
Average, Max, Min current
Same as above, but for current. The data-send sessions are clearly recognized by the use of these
parameters.
Operating cycle
This virtual sensor measures the time that the data logger is awake, performing tasks. This gives also
good diagnostic information. When i.e. the GSM signal is very weak, retries will occur, and the session
will consume more time. This parameter provides information on the proper operation of a system. The
Operating cycle is measured in seconds.
Free disk space
Shows the remaining disk space on the SD Card. In most cases there is sufficient space left.