Operating Y
our
Spa
11
OC Hot Tubs Owner’s Manual
LTR50001045, Rev. N
Operating Your Spa
Spa Topside Control - One and Two Pump Systems
Initial Start-up (Two pump systems)
Temperature Adjustment
(Range 80°F to 104°F, 26°C to 40°C)
The electronic control panel displays the actual water
temperature in degrees Fahrenheit. The displayed
temperature will only be current after the pump has been
running for at least two minutes.
To display the temperature that the hot tub is set to:
• Press the
Temp
button. The temperature setting will
flash.
• While the display is flashing, each time you press
Temp
button, the set temperature will change up or
down one degree.
• If the desired temperature is opposite of the direction
each press of the button is making, release button,
allow display to stop flashing and then press
Temp
button to change temperature in the other direction.
For one pump systems
For two pump systems
When first powered up, your hot tub will perform a self-
diagnostic check and go into priming mode. When the
control panel displays
PR
, IMMEDIATELY do the following:
1. Press the JETS 1 or JETS 2 button to turn on the pump
and let it run for 10 seconds. The pump should be
running in low speed.
2. Press the JETS 1 or JETS 2 button again and let the
pump run in high speed for 10 seconds.
3. Press the JETS 1 or JETS 2 button again to turn off the
pump. The pump should be left in the off position for
10 to 15 seconds.
4. Repeat steps 1 through 3 until water is flowing through
all the jets and all air is removed from the plumbing.
When the hot tub has finished priming, the heater will be
activated and the water temperature will be maintained in
standard mode. The hot tub will heat to 100°F (37.5°C) at
start up until the set temperature is changed as described.
When first powered up, your hot tub will perform a self-
diagnostic check and go into priming mode. When the
control panel displays
PR
, IMMEDIATELY do the following:
1. Press the JETS button to turn on the pump and let it
run for 10 seconds. The pump should be running in low
speed.
2. Press the JETS button again and let the pump run in
high speed for 10 seconds.
3. Press the JETS button again to turn off the pump. The
pump should be left in the off position for 10 to 15
seconds.
4. Repeat steps 1 through 3 until water is flowing through
all the jets and all air is removed from the plumbing.
When the hot tub has finished priming, the heater will be
activated and the water temperature will be maintained in
standard mode. The hot tub will heat to 100°F (37.5°C) at
start up until the set temperature is changed as described.
Initial Start-up (One pump systems)