Operating Y
our
Spa
13
OC Hot Tubs Owner’s Manual
LTR50001045, Rev. N
Message
Meaning
Action Required
No message
on display
1) Spa temperature is unknown.
1) After pump has been running for 2 minutes, temperature
will be displayed.
2) Spa is in Economy or Sleep mode.
2) In Economy or Sleep mode, the pump may be off for
hours outside a filter cycle. If you wish to see the current
spa temperature, either switch to Standard mode or turn
Jets1 on for at least two minutes.
3) Power has been cut off to the spa.
3) The control panel will be disabled until power returns.
Spa settings and time of day will be preserved for 30 days
with a battery back-up.
--
Temperature unknown.
After the pump has been running for two minutes, the
temperature will be displayed.
dr
Insufficient water detected in heater.
Spa will be shut down for 15 minutes.
Check water level in spa. Refill if necessary. Make sure
pumps are been primed and filter cartridges are clean.
Press any button to reset or wait 15 minutes and spa will
automatically reset. If spa message does not reset, call OC
Hot Tubs customer service for guidance.
dY
Insufficient water detected in heater.
Spa is shut down.
(Displays on third occurrence of dr
message.)
Follow directions for dr message and press any button to
reset spa. Spa will not automatically reset when dry or dY is
displayed.
Ec
Indicates heater is in Economy Mode.
None.
HH
OHH
Overheat protection (spa is shutdown).
One sensor has detected 118˚F (48˚C)
at the heater.
DO NOT ENTER THE WATER!
Remove the spa cover and allow spa to cool below 107˚F
(42˚C). Press any button on the topside display to reset
spa. If spa will not reset after spa has cooled, turn off
power for approximately 30 seconds and then turn power
back on. If display message is repeated, then shut the
power off to the spa and call OC Hot Tubs customer service
for guidance.
HL
HFL
A difference in readings between
temperature sensors has been detected
indicating a possible water flow
problem.
Make sure spa is filled to proper level and that pumps are
primed and filter cartridges are clean. If message does not
reset, call OC Hot Tubs customer service for guidance.
IC
ICE
Potential freeze condition detected.
No action required. The pumps and the blower will
automatically activate regardless of spa status.
Your new hot tub comes equipped with an electric heater.
Following the directions listed below will ensure the most
efficient operation:
NOTE: This method is only for hot tub usage under two
hours a week.
• Keep the hot tub’s operating temperature 5˚F below
the desired usage temperature when not in use. One
or two hours before use, set the temperature to the
desired temperature.
• If the hot tub usage exceeds two hours a week, the
set temperature should remain at the desired usage
temperature.
• The air venturis should be used sparingly. When open,
water temperature drops quite rapidly and can also
dissipate chemicals.
Allowing the water temperature to lower more than 10˚F
below the desired usage temperature and reheating it prior
to usage will cause the heater to operate longer than it
normally would maintaining the desired temperature. Doing
this will increase your operating cost and makes your heater
work more than necessary.