Version 5.2_2022 (January 26, 2022)
22
Water connection, see photo:
8.6.
Commissioning
The installation of the Aqua Cool must comply with the general and locally applicable building, safety and
installation regulations of the local authorities and the electricity and water companies.
Connect the power supply to the wall socket as shown in the electrical diagram supplied. Connect the unit on
the water side using the Bauer couplings. The supply is the female, the return is the male.
8.7.
Pre-commissioning check
- Check the points mentioned in chapter 8.
- If present, check the water circuit and especially all connections for leaks.
- Check whether there is sufficient water pressure in the hydraulic system.
- Check that air inlet and outlet can take place unhindered.
- Check that the correct supply voltage is present.
- Check that the unit is still level even after the ducts and any pipes have been connected and the
system has been filled.