11
Cut the mains cable to a length of 5 cm
and strip the insulation from the ends.
Sento verticale up
Place the mounting plate over the
power outlet and against the wall, and
turn it until the elongated holes are
oriented as required. Mark the positions
where the holes are to be drilled. Orient
the threaded holes vertically.
Check the routing of the power
cables.
Drill two 6 mm diameter holes, push in
the rawlplugs so that they lie flush and
screw on the mounting plate (screws
and rawlplugs are included in the scope
of delivery).
Ensure that the screws finish flush with
the mounting plate.
Using a screwdriver, open the flap in the
middle of the converter.
Click!
$
Caution:
Before fitting, disconnect all current-
carrying lines from the mains supply.
Lock the converter into the mounting
plate so that it is fitted flush.
At the same time, guide the ends of
the mains cable through the converter
opening.