Electrical Requirements |
5/25/05
2-7
2.2.2
Printer Power Requirements
The printer operates in the following two configurations.
Delta (USA/Canada) Configuration:
Voltage:....................../-10%, 3 Phase
Frequency:.................50 or 60 Hz
Current:......................25AMPS maximum steady state
Power: .......................15kW max.
Circuit Breaker...........30 Amps
Wye (European) Configuration:
Voltage:....................../-10%, 3 Phase
Frequency:.................50 or 60 Hz
Current:......................13AMPS maximum steady state
Power: .......................15kW max.
Circuit Breaker...........30 Amps
1
It is recommended that the AC power outlet for the printer be located within 8 feet of the
power inlet on the printer.
2.2.3
Vacuum Pump Power Requirements
The vacuum pump operates over the following range of voltages and frequencies:.
230 Volts @ 60HZ
Voltage:......................230 VAC +/-10%, 3 Phase
Current:......................13 AMPS maximum steady state
Power: .......................6kW max.
Circuit Breaker...........20 Amps
400 Volts @ 60Hz
Voltage:......................400 VAC +/-10%, 3 Phase
1. Short circuit protection must be provided in the wiring of the building where the printer is
installed.