Extended Line Printer Server
Editing of the configuration file (printcap and lpd.ini)
A29247-X30-X-9-70 US
199
Note:
The queue names are CASE SENSITIVE!
There are two variants of parameters, namely string and numerical parameters. String pa-
rameters are of the form "parameter_name=value" where value is everything starting right
after the equal sign up to the next ":" or end of line. If the value is to include the special char-
acters ":", " ", "#", "@", they must be escaped by a preceding "\", e.g. "fm=Form\#0" means
that the value of "fm" is "Form#0" etc. Note that such characters are only allowed for the
Form object. The '/:'should be used in the last object (Form) as ':'is also a separator.
Numerical parameters are of the form "parameter_name#value" where value is a decimal
number, e.g. "mc#100" means the value of "mc" is 100.
The currently supported parameters are as follows:
Note:
Set the job ticket file to read-only, otherwise it will be deleted after first use. Other
parameters should not be specified to maintain compatibility with future products.
Errors are logged to the Windows Application Event Log.
Name
Type
Default
Description
cl
String
””
Job class
fm
String
STD
Form name.
The form name can be changed dynamically via the docu-
ment title. The document title which is given to the lp or lpr
command has to start with ‘
fm=xxx
” where xxx designs the
form name.
jt
String
No default
Job ticket template file, equivalent to ‘-T’ option to osp-
print.exe. If the file name does not start with an absolute
path, C:\OceSpool\Lpd\Tickets (in default setup) is
prepended automatically
mc
Numerical
0
Max number of copies, 0 means no limit.
However, there is a hard coded internal limit of 9999.
If a print job exceeds either limit the number of copies is
truncated to the allowed maximum
sn
String
””
Printer name/number
cn
String
No default
The only possible value for this parameter is "cj" : when the
paremeter value is "cj", the Document Name within the
PRISMAspool job ticket will be set from the "J" parameter
the lpd command rather than from the "N" parameter.
Summary of Contents for PRISMAspool
Page 1: ...Océ Océ User Guide Océ PRISMAspool V4 04 ...
Page 4: ...A29247 X30 X 9 70 US ...
Page 5: ...Appendix Glossary Annexes Index ...
Page 6: ...A29247 X30 X 9 70 US ...
Page 20: ...PRISMAspool Licenses Description of PRISMASpool V4 04 20 A29247 X30 X 9 70 US ...
Page 56: ...Software Modification Packages Installation 56 A29247 X30 X 9 70 US ...
Page 204: ...Advanced settings Extended Line Printer Server 204 A29247 X30 X 9 70 US ...
Page 222: ...Configuration of a WPE printer Windows Print Extension 222 A29247 X30 X 9 70 US ...
Page 231: ...Submitting a job PJM Server A29247 X30 X 9 70 US 231 Now let fire a test job via PJM ...
Page 234: ...PJM Server Fast Range Printing for big Files larger than 4 GB 234 A29247 X30 X 9 70 US ...
Page 252: ...Print Manager Web Setting up Microsoft Internet Information Services 252 A29247 X30 X 9 70 US ...
Page 308: ...Appendix 308 A29247 X30 X 9 70 US ...
Page 312: ...Glossary 312 A29247 X30 X 9 70 US ...
Page 327: ...Annex III How to configure a SCSI printer in Windows Annexes A29247 X30 X 9 70 US 327 ...
Page 390: ...Annexes Annex XII How to install the LPR Client on Windows 7 390 A29247 X30 X 9 70 US ...