7.3.4.7 Replacing the discharge corotron (torn wire)
288
A29246-X20-X-4-7680 / fa703.fm
Install new discharge corotron
2.
Remove corotron cartridges.
Caution
When removing the discharge corotron cartridge, the nipple on the corotron wire may
fall into the developer station without you noticing. If printing then continues, the
developer station can be irreparably damaged.
When changing the faulty discharge corotron cartridge, always check if the nipple is
still on the corotron wire. If the nipple is missing, search for and find it.
3.
Check whether the nipple is still in on the corotron wire. If the nipple is missing,
search for it. To do this, pull out the developer station (
see section 6.7 Cleaning the
developer station, page 203)
and search the developer station and the entire area
around it. If no nipple is found, remove the photoconductor drum and search this
area.
Important
Observe the safety directives before replacing corotrons (
see section 7.3.4 Replacing
corotrons, page 269)
.
Proceed as follows:
2 of 2
Summary of Contents for VarioStream 7000 SINGLE
Page 1: ...Oc Oc Operating Manual Oc VarioStream 7000 SINGLE Pinfed...
Page 4: ......
Page 24: ...1 8 Statutory requirements 24 A29246 X20 X 4 7680 all103 fm...
Page 58: ...3 5 Paper feed options 58 A29246 X20 X 4 7680 fa301 fm...
Page 208: ...6 8 1 Cleaning the toner mark sensor 208 A29246 X20 X 4 7680 fa603 fm...
Page 354: ...8 6 Permitting or blocking remote access 354 A29246 X20 X 4 7680 fa805 fm...
Page 373: ...Technical data A29246 X20 X 4 7680 faA01 fm 373 Weight Approx 1 260 kg simplex printing system...
Page 374: ...Technical data 374 A29246 X20 X 4 7680 faA01 fm...
Page 384: ......