7.3.4.8 Complete corotron replacement
290
A29246-X20-X-4-7680 / fa703.fm
7.3.4.8 Complete corotron replacement
Proceed as follows:
1.
Corotron locks are checked.
If this step cannot be completed, re-open and close the locking mechanism of the
corotron mountings.
2.
Close both front doors and the cover of the printing system.
3.
Click the following button to lower corotrons:
4.
Enter on the operator panel whether a new corotron was fitted:
•
The message on the operator panel is deleted automatically, the replacement of
the corotrons is recorded in the <Consumables history> menu and the consumable
counter is reset.
•
The consumable counter is not reset.
5.
Click the following button on the operator panel to complete corotron replacement:
All printing system assemblies are checked (duration approx. 2-3 minutes) before
the printing system is switched to the "Ready" status.
In both cases, the message on the operator panel is automatically deleted, the
replacement of the corotrons is recorded in the <Consumables history> menu and
the consumable counter is reset.
Summary of Contents for VarioStream 7000 SINGLE
Page 1: ...Oc Oc Operating Manual Oc VarioStream 7000 SINGLE Pinfed...
Page 4: ......
Page 24: ...1 8 Statutory requirements 24 A29246 X20 X 4 7680 all103 fm...
Page 58: ...3 5 Paper feed options 58 A29246 X20 X 4 7680 fa301 fm...
Page 208: ...6 8 1 Cleaning the toner mark sensor 208 A29246 X20 X 4 7680 fa603 fm...
Page 354: ...8 6 Permitting or blocking remote access 354 A29246 X20 X 4 7680 fa805 fm...
Page 373: ...Technical data A29246 X20 X 4 7680 faA01 fm 373 Weight Approx 1 260 kg simplex printing system...
Page 374: ...Technical data 374 A29246 X20 X 4 7680 faA01 fm...
Page 384: ......