37 of 59
Battery Charger Instance 0
First Connected Battery Data Registers
Hex Addr
Dec
Addr
Data Field
Data Type, Range and Resolution
0x0177
0375
Operating State
Charge Mode
Charger Enab/Dis
Equalisation Pend
16 bit field
xxxx xxxx xxxx 0000 = Not Charging
xxxx xxxx xxxx 0001 = Bulk
xxxx xxxx xxxx 0010 = Absorption
xxxx xxxx xxxx 0011 = Overcharge
xxxx xxxx xxxx 0100 = Equalise
xxxx xxxx xxxx 0101 = Float
xxxx xxxx xxxx 0110 = No Float
xxxx xxxx xxxx 0111 = Constant VI
xxxx xxxx xxxx 1000 = Disabled
xxxx xxxx xxxx 1001 = Fault
xxxx xxxx xxxx 1110 = Error
xxxx xxxx xxxx 1111 = Data not available
xxxx xxxx 0000 xxxx = Standalone Mode
xxxx xxxx 0001 xxxx = Primary Mode
xxxx xxxx 0010 xxxx = Secondary Mode
xxxx xxxx 0011 xxxx = Echo Mode
xxxx xxxx 1110 xxxx = Error
xxxx xxxx 1111 xxxx = Data not available
xxxx xx00 xxxx xxxx = Charger Off/Disabled
xxxx xx01 xxxx xxxx = Charger On/Enabled
xxxx xx10 xxxx xxxx = Error
xxxx xx11 xxxx xxxx = Unknown/Unavailable
xxxx 00xx xxxx xxxx = Eq Pend Off/Disabled
xxxx 01xx xxxx xxxx = Eq Pend On/Enabled
xxxx 10xx xxxx xxxx = Eq Pend Error
xxxx 11xx xxxx xxxx = Unknown/Unavailable
0x0178
0376
Equalisation Time
remaining
Unsigned 16 bit integer
Range 0 – 65,532 Minutes
Resolution 1 minute
Second Connected Battery Data Registers
0x0179
0377
Operating State
Charge Mode
Charger Enab/Dis
Equalisation Pend
16 bit field
xxxx xxxx xxxx 0000 = Not Charging
xxxx xxxx xxxx 0001 = Bulk
xxxx xxxx xxxx 0010 = Absorption
xxxx xxxx xxxx 0011 = Overcharge
xxxx xxxx xxxx 0100 = Equalise
xxxx xxxx xxxx 0101 = Float
xxxx xxxx xxxx 0110 = No Float
xxxx xxxx xxxx 0111 = Constant VI
xxxx xxxx xxxx 1000 = Disabled
xxxx xxxx xxxx 1001 = Fault
xxxx xxxx xxxx 1110 = Error
xxxx xxxx xxxx 1111 = Data not available
7.16
Battery Charger Instance 0 Registers