background image

9 of 12

3.2 DEVICE INSTANCE

It is possible to install 16 3420 AC Monitors on a NMEA2000® network so they need to each have 

a unique Device Instance Address. The Device Instance of each unit is set by turning the small 

rotary switch with a small screw driver. Valid Device Instances range from “0” through to “F”.

NMEA2000® Parameter Group Numbers (PGNs)

Note: The “line to line” voltage values on PGNs PGN127747, PGN127748 and PGN127749 are 

calculated from “line to neutral” voltage (not available on single phase, VLL = VLN • 2 for 

2-phase and VLL = VLN •  for 3-phase setup).

Note: The frequency values on PGNs PGN127747, PGN127748 and PGN127749 are the same as the 

system frequency. They are not measured on each phase separately.

Note: The power values on PGNs PGN127744, PGN127745 and PGN127746 are calculated from 

the measured voltage and current values (P = U • I).

Type

PGN No

PGN Name

Monitor

PGN127744

AC Power / Current- Phase A

PGN127745

AC Power / Current- Phase B

PGN127746

AC Power / Current- Phase C

PGN127747

AC Voltage / Frequency-Phase A

PGN127748

AC Voltage / Frequency-Phase B

PGN127749

AC Voltage / Frequency-Phase C

Protocol

PGN126464

Tx/Rx PGN List

PGN126996

Product Information

PGN126998

Configuration Information

PGN059392

ISO Acknowledge

PGN059904

ISO Request

PGN060928

ISO Address Claim

PGN126208

Command/Request Group

Summary of Contents for NMEA2000 3420

Page 1: ...NMEA2000 AC MONITOR Part Numbers 3420 USER MANUAL Revision 2 00 ...

Page 2: ......

Page 3: ...Unpacking the box 3 2 2 Mounting the unit 3 2 3 Connecting the NMEA2000 Cable 3 2 4 Connecting the sensor cables to the WAGO socket 4 2 5 AC Monitor Connections 5 3 Configuration 6 3 1 Configuring Circuit Type 6 3 2 Device Instance 9 4 Warranty 11 5 Technical Support 12 ...

Page 4: ... up correctly according to this manual Please read and follow the installation and setup instructions carefully to achieve the best results 1 2 PRODUCT FEATURES The NMEA2000 3420 AC Monitor has the following features Inputs from AC voltage Max 280 VAC 200 Amp AC Current Transformer User Settable Device Instance using rotary switches User Settable Circuit Type Heartbeat blue LED confirming NMEA tra...

Page 5: ...cations are shown on the following drawing Note Mount away from sources of condensation and moisture 2 3 CONNECTING THE NMEA2000 CABLE The unit is connected to the NMEA2000 network by the 5 way micro C socket on the front Carefully attach the network drop cable to this plug and hand tighten until it it is fully seated Take care to match the orientation of the pip inside the socket to the recess in...

Page 6: ...ED ELECTRONICS ENGINEER ONLY The cables from the power source to the external sockets are connected using the 6 x 2way WAGO Cage Clamp terminal block The wire should be stripped for 8mm and then the cage clamp opened with a small screwdriver in the slot above the wire connection Then simply insert the wire into it s connection slot and release the cage clamp by removing the small screw driver This...

Page 7: ... Terminal 3 Current Transformer Phase C 2 Terminal 4 Voltage Phase A Line Fit in line 3 Amp fuse Terminal 5 Voltage Phase B Line Fit in line 3 Amp fuse Terminal 6 Voltage Phase C Line Fit in line 3 Amp fuse Terminal 7 Current Transformer Phase A 1 Terminal 8 Current Transformer Phase B 1 Terminal 9 Current Transformer Phase C 1 Terminal 10 No Connection Terminal 11 Neutral Terminal 12 No Connectio...

Page 8: ...e set up When turning on the AC monitor for the first time the blue LED will flash quickly to indicate it s not set up The AC Monitor is set up by turning the small rotary switch with a small screw driver to the required setting and then pressing the button for 5 seconds Be sure to return the switch to the correct instance setting afterwards Note You can always change the set up of the AC monitor ...

Page 9: ...7 of 12 Two Phase Connection ...

Page 10: ...8 of 12 Three Phase Connection ...

Page 11: ...etup Note The frequency values on PGNs PGN127747 PGN127748 and PGN127749 are the same as the system frequency They are not measured on each phase separately Note The power values on PGNs PGN127744 PGN127745 and PGN127746 are calculated from the measured voltage and current values P U I Type PGN No PGN Name Monitor PGN127744 AC Power Current Phase A PGN127745 AC Power Current Phase B PGN127746 AC P...

Page 12: ...efinately Load Dump Protection Yes SAE J1113 Size mm 96 x 84 x 35 Weight gr 120 Parameter Value IEC 60954 Classification Protected Degree of Protection IP40 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Electromagnetic Emission Conducted and Radiated Emission per IEC 60945 9 ...

Page 13: ...UENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OCEANIC SYSTEMS AGGREGATE LIABILITY EXCEED THE PURCHASE PRICE OF THE PRODUCT S INVOLVED OCEANIC SYSTEMS SHALL NOT BE SUBJECT TO ANY OTHER OBLIGATIONS OR LIABILITIES WHETHER ARISING OUT OF BREACH OF CONTRACT OR WARRANTY TORT INCLUDING NEGLIGE...

Page 14: ...ve New Milton Hampshire BH25 6RH United Kingdom Tel UK 44 0 1425 610022 Tel USA 844 898 6462 Fax 44 0 1425 614794 Email sales osukl com Web www osukl com Copyright 2019 Oceanic Systems UK Ltd All rights reserved Our policy is one of continuous product improvement so product specifications are subject to change without notice Oceanic Systems products are designed to be accurate and reliable However...

Reviews: