143
FREE DIVE EDT (ELAPSED DIVE TIME) ALARM
The FREE EDT Alarm is factory set for 30 seconds. When set ON, the Alarm will sound 3
short beeps and the message TIME will be displayed momentarily every 30 seconds while
the ATOM is operating underwater in FREE DIVE Mode.
Depressing the A and S buttons simultaneously for 2 seconds while the FREE SURF
MAIN screen is displayed, will access SET FREE EDT ALARM with the Set Point
flashing.
NOTE: The FREE EDT Alarm can only be Set
(turned OFF or ON) while on the Surface and can
not be changed during a Dive.
SET FREE EDT ALARM DISPLAY,
information includes (Fig. 131) -
> Graphic EDT.
> Set Point OFF or ON, flashing.
Pressing and releasing the S button momentarily (< 2
seconds) will toggle the Set Point between OFF and ON.
Pressing the A button momentarily (< 2 sec) will accept the
setting and access the SET FREE DEPTH ALARM 1 screen.
Depressing the M button for 2 seconds, or if no button is
pressed during a period of 2 minutes, will revert the
Display to the FREE SURF MAIN screen.
Fig. 131 - SET FREE EDT
ALARM
The Set Point for the
NORM/GAUG EDT
Alarm does not
affect the FREE EDT
Alarm.