144
FREE DIVE DEPTH ALARMS (FDA)
The ATOM features 3 FREE Dive DEPTH Alarms that can be Set
at progressively deeper Depths and turned OFF/ON.
> If Alarm 1 is set OFF, then Alarms 2 and 3 will be disabled.
> If Alarm 2 is set OFF, Alarm 3 will be disabled.
When each of the Depths are reached during a dive, 3 short
beeps will sound 3 times and the message DPTH will be dis-
played 3 times.
Pressing the A button momentarily (< 2 seconds) while the
SET FREE EDT ALARM screen is displayed will access SET
FREE DEPTH ALARM 1 with the Set Point flashing.
Sequence of FREE Mode Alarm Setting Access:
FREE SURF MAIN press A and S 2 seconds >>
SET FREE EDT AL press A less than 2 seconds >>
SET FREE DEPTH AL 1 press A less than 2 seconds >>
SET FREE DEPTH AL 2 press A less than 2 seconds >>
SET FREE DEPTH AL 3 press A less than 2 seconds >>
FREE SURF MAIN
Responsible
Responsible
The Set Point for the
NORM/GAUG
Depth Alarm does
not affect the FREE
Depth Alarms.